Z3S-TW22 JULONG Color mark Sensor Bag making machine Photoelectric sensor
Technical Parameters
Checking mode |
Coaxial |
Checking distance |
10mm +/- 2mm |
Voltage supply |
DC10-30V +/- 10% Wave <10% |
Work currency |
Under 45mA |
Light source spectrum |
Red, green, blue, white,optional |
Light spot |
Φ0.5~Φ1.5 |
Checking angle |
Vertical with surface, with 15°tolerance |
Response time |
0.1~1ms |
Output mode |
Operate with light or without light |
Output indication |
Red LED |
Output voltage |
VH <=VC-1.5V VL <= 1.2V |
Currency load |
200mA(max) |
Circuit protection device |
Vc polar protection short-circuit protection |
Sensitivity |
Single loop adjustable |
Anti-background light |
Sunlight < 10000 Lx incandescent light<3000Lx |
Protection level |
Ip67 |
Environment protection temperature |
Work at -15℃~65℃ storage -25℃~80℃ |
Shell material |
Metal |
Connection wire |
Φ5.4 PVC 4-core cable L=2m |
Weight |
About 500g |
Operation
Firstly, select the output state(Dark switching or Light switching), then to adjust the sensitivity.
Darking switching output adjustment methods
1. Turn the output option switch to dark switching, (no matter the spot aims at dark color or light color ) clockwise the sensitivity rotary knob to light the indicator light( light on means control output on, otherwise output shut off. )
2. Aim the spot at dark color piece(color code), adjust sensitivity knob, indicator light on, remember the position A this knob turned.
3. Then aim the spot at the light color piece(bottom color), clockwise adjust the knob, indicator light on, remember the position B this knob turned.
4. Finially, put the knob back to the middle place between A and B.
Note: because this sensiivity control is multiturn potentiometer, when adjusting, you need to remember the position A and B, as well as remember how many rounds from A to B, and how many rounds when back to the middle of A and B.
Light switching output adjustment methods
1. Turn the output option switch to light switching, (no matter the spot aims at dark color or light color ) anticlockwise the sensitivity rotary knob to light the indicator light
2. Aim the spot at light color piece(bottom color), adjust sensitivity knob, indicator light on, remember the position A this knob turned.
3. Then aim the spot at the dark color piece(color code), anticlockwise adjust the knob, indicator light on, remember the position B this knob turned.
4. Finially, put the knob back to the middle place between A and B.
Note: because this sensiivity control is multiturn potentiometer, when adjusting, you need to remember the position A and B, as well as remember how many rounds from A to B, and how many rounds when back to the middle of A and B.