Products
Search
Categories
Electronics Product Beauty / Personal Care Furniture / Building Materials Automotive Machinery Clothing Accessories Home Department Store International Logistic Service
Contact Supplier
To: Annie Fu

Urine glucose test strips kits rapid test rapid diagnostic test kit

Product parameters

Product Details
Product Description
Product Description

 

Flexible:Available in up to 12 parameters

Urine Reagent Strips (URS) for Urinalysis are firm plastic strips to which several different reagent areas are affixed. Depending on the product being used, Urine Reagent Strips provide tests for Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes, and Ascorbic Acid in Urine. Test results may provide information regarding the status of carbohydrate metabolism, kidney and liver function, acid-base balance, and bacteriurea.1,2 Please refer to the outside box and bottle label for the specific test parameters of the product you are using

A urine test strip is a basic diagnostic instrument used to determine pathological changes in the urine in standard urinalysis. A standard urine test strip may comprise of up to 12 different chemical pads or reagents which react (change color) when immersed in, and then removed from, a urine sample. The test can be read between 60 and 120 seconds after dipping. Routine testing of the urine with multiparameter strips is the first step in the diagnosis of a wide range of diseases

 

Visual Reading Technique:

  • Hold the strip up horizontally and compare the result shown on the strip with the color chart on the canister label closely and carefully. Take note of the result. For a semi-quantitative result, take down the results according to the time specified on the color chart. The pH and Protein can be read at any time within 60 seconds after dipping. For a qualitative result, the strip should be read 1-2 minute after dipping. If a positive result is obtained, repeat the test and compare with color chart at the time specified. Color changes beyond 2 minutes are of no diagnostic value.

Our factory produces with a competitive price. The relevant quotation and samples will be sent upon request

Dip the test strip for about 1 second into the fresh urine specimen

496386415_723.jpg

Wipe off any excess urine on the rim of the vessel and blot the edge of the test strip on tissue paper

rapid test kit rapid diagnostic test kit rapid test kit id now molecular test kit antibody rapid malaria rapid test kit rapid antigen test kit cpv rapid test kit kits rapid test rapid test kit covid rapid test kit 19 rapid test kit antigen rapid beard test kit typhoid rapid test kit maleria rapid test kit antigen rapid test kit antibody rapid test kit h pylori rapid test kits chlamydia rapid test kits typhoid rapid test kit ctk ectest rapid diagnostic test kits test rapid kit assembly machine fertility rapid test kit hiv rapid test kit blood rapid test kit std rapid test kits dengue rapid test kit rapid test kit reagent uti home rapid test kit test kit antibody rapid clungene aflatoxin b1 rapid test kits rapid test kit vitamin d typhoid rapid test kit ctk germani pcr test kit rapid rapid test kit igm rapid microbiological water testing kit pcr test kit rapid cost test kit rapid hiv test kit rapid crona test kit rapid crona test hjian kit rapid rapid test kits assembly line rapid diagnostic test kit igg/igm test kit antibody rapid toxoplasma gondi antigen saliva swab diagnostic rapid test kit rapid hiv test kits test kit antigen rapid rapid sara test kits rapid test kit manufacture veterinary rapid test kit rapid microbiological test kit sars rapid test kit rapid sar test kit rapid test kit nasal rapid test kit adtech sickle cell rapid test kits rapid test kit paud pune rapid test kits assembky line malaria rapid diagnostic test kit antibody rapid test kit sars rapid antibiotic test milk kit fosun pcr rapid test kit test kit antibody rapid fda poct rapid test kit assembly line staphylococcus aureus home rapid test kit ivd poct rapid test kit assembly line rapid test kit igg igm (colloidal gold) rapid antigen test drop test kits rapid test kit suppliers rapid test kit machine rapid drugs test kits virus rapid test kits brucellosis rapid test kit antibiotic rapid test kit ag rapid test kit test d'urine rapide kit rapid test kit price anigen rapid test kit

 Testing Items:  Leucocyte Nitrite Urobilinogen Protein pH Blood Specific Gravity Ketone Bilirubin Glucose

  • Glucose
    This test is based on a sequential enzyme reaction. First, glucose oxidase catalyzes the formation of gluconic acid and hydrogen peroxide from the oxidation of glucose. A second enzyme, peroxidase, catalyzes the reaction of hydrogen peroxide with potassium iodide chromogen to oxidize the chromogen to colors ranging from blue through greenish-brown, and brown to dark-brown.
    Reactivity of the test decreases as the specific gravity and/or pH of urine increases, and may also vary with temperature. Ascorbic acid (more than 50 mg/dl) and ketone bodies (more than 40 mg/dl) may cause a false negative result for a specimen containing a small amount of glucose (100 mg/dl). However, the combinations of such ketone levels and low glucose levels are metabolically improbable..

Read the result by comparing the test fields with the color scale on the test pack after 30 to 60 seconds

rapid test kit rapid diagnostic test kit rapid test kit id now molecular test kit antibody rapid malaria rapid test kit rapid antigen test kit cpv rapid test kit kits rapid test rapid test kit covid rapid test kit 19 rapid test kit antigen rapid beard test kit typhoid rapid test kit maleria rapid test kit antigen rapid test kit antibody rapid test kit h pylori rapid test kits chlamydia rapid test kits typhoid rapid test kit ctk ectest rapid diagnostic test kits test rapid kit assembly machine fertility rapid test kit hiv rapid test kit blood rapid test kit std rapid test kits dengue rapid test kit rapid test kit reagent uti home rapid test kit test kit antibody rapid clungene aflatoxin b1 rapid test kits rapid test kit vitamin d typhoid rapid test kit ctk germani pcr test kit rapid rapid test kit igm rapid microbiological water testing kit pcr test kit rapid cost test kit rapid hiv test kit rapid crona test kit rapid crona test hjian kit rapid rapid test kits assembly line rapid diagnostic test kit igg/igm test kit antibody rapid toxoplasma gondi antigen saliva swab diagnostic rapid test kit rapid hiv test kits test kit antigen rapid rapid sara test kits rapid test kit manufacture veterinary rapid test kit rapid microbiological test kit sars rapid test kit rapid sar test kit rapid test kit nasal rapid test kit adtech sickle cell rapid test kits rapid test kit paud pune rapid test kits assembky line malaria rapid diagnostic test kit antibody rapid test kit sars rapid antibiotic test milk kit fosun pcr rapid test kit test kit antibody rapid fda poct rapid test kit assembly line staphylococcus aureus home rapid test kit ivd poct rapid test kit assembly line rapid test kit igg igm (colloidal gold) rapid antigen test drop test kits rapid test kit suppliers rapid test kit machine rapid drugs test kits virus rapid test kits brucellosis rapid test kit antibiotic rapid test kit ag rapid test kit test d'urine rapide kit rapid test kit price anigen rapid test kit 

VISUAL READING TECHNIQUE:

  1. Immerse all reagent areas in specimen and remove strip immediately.
  2. Run edge of strip against the rim of the container to remove excess urine.
  3. Compare test areas closely with colour chart on bottle label or bench reader. Record the results.

VISUAL READING TECHNIQUE.jpg

Instruction:

  • Dip the test patch of a fresh strip into urine sample, or pass strip through urine stream 1 to 2 seconds only.
  • Blot excess on a clean paper towel or tissue.
  • Results may be compared between 1 minute od exposure to urine(colour changes occuring after 1 minute are of no diagnostic value)

product mix.jpg

Notes:

  1. Do not touch test areas of reagent strips.
  2. Do not use after expiry date
  3. Do not remove desiccant(s).
  4. Do not remove strip from the bottle until immediately before it is to be used for testing.
  5. Replace cap immediately and tightly after removing reagent strip.
  6. Store at temperature between 2°C-30°C.
  7. Store only in original bottle.
  8. The sample should not be more than 4 hours old at the time of testing.
  9. Collect fresh urine in a clean dry container.
Detailed Images

 urine reagent strips (19).JPGurine reagent strips (20).JPGurine reagent strips (21).JPGurine reagent strips (42).JPGurine reagent strips (50).JPGurine reagent strips (51).JPG

Package & Storage

Package & Storage.jpg 

Payment & Delivery

Packing & Delivery 

Certifications

CE Certificates 

Our Services

1. Our service

 

Gemc are synonymous with quality, personalized service and a commitment to excellence.  With our specialized rapid, diagnostic test technologies, high quality assurance, brand recognition, innovative research and development techniques, customer-centric design, an experienced management team, and an energetic sales force, Gemc continues to set the standards in product quality and reliability.  We believe in continually improving our products and service, and making the business relationship a beneficial experience for both customers and employees.  

 

 

 Based on our core competence in rapid test technology, high quality assurance in products, international renowned brand name, innovative R&D, customer-centric product design as well as strong sales network, the experienced management team and energetic sales force of Gemc will lead our life to achieve peacefulness, harmony, and higher quality.

 

 

2. How to order our product

 

(1) Customers to contact to consult , and purchase our products

(2) Our trader make a perfessional form according to your product

(3) Inform the product you need after you confirmation of the product

FAQ

Q1: What's the method u use to do the test?
A: Colloidal Gold Method.


Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.


Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.


Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.
 
Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.


Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:Technical data: Such as the accuracy, specificity and sensitivity.
Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.

Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.

Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice

Contact us

Telephone: 86-371-60997506  

             Fax: 86-371-60997506

     Website: http://www.gv-medic.com
    Address: NO.20,Bosong Road, Zhengzhou, Henan ,China

              Zip: 450001
            City: Zhengzhou

    Country: China (Mainland)

Electric Golf Cart
Inquiry Whatsapp: +44 7522 566048