All categories
All categories
All categories
All categories

Thermal Gas Mass Flowmeter (MEGA-TMF600)

Other recommendations for your business

Description

MEGA-TMF600 measures the gas mass flow based on Thermal Diffusion principle. One sensor measures the velocity of gas flow (Rh) and the other sensor detects the temperature shift of gas flow (Rmg). When there are two RTDs in the gas flow, Rh will be heated and Rmg will sense the temperature difference. As the velocity of gas flow increases, more heat will dissipate and so the temperature read by Rh will decline.

MEGA-TMF600 Thermal Mass Flowmeter design is based on a constant power measuring method, thus the RTD is heated on a consistent power and will be more durable and stable. Due to that, TMF-450 meter has less problem of zero-off which may cause a function failure of RTD due to overheating the term.

 

  • The dual line LCD display with 3 setting button
  • Wide Turndown ratio of 100:1, can also be expended to 200:1
  • No pressure loss and it can be used on pipes from DN25 to DN2000
  • It has a more compact design, which means smaller enclosure and thinner insertion tube probe
  • Measure mass flow and standard flow directly
  • It has a self-diagnostic function
  • It has high accuracy data acquisition circuit
  • High effective design of power supply
  • It can be installed/removed without stopping the process
  • Cost-effective model
  • Ex-proof version optional
  • Electrical structure of total isolation to ensure excellent EMC properties and avoid the interference from outside

Specifications

Media capability Air, Nitrogen, O2, CO2, Argon, CH4, Natural gas, biogas, and almost all dry and clean air
Pipe diameter DN25-DN2000
Flow velocity range 0.3-30, 0.6-60, 0.9-90, 1.2-120, 1.5-150Nm/s
Accuracy ±1.5% FS
Maximum Pressure 1.6MPa (std), 2.5MPa, 4MPa, 6.3MPa (opt)
Temperature of medium -40 °F to 302 °F (-40 °C to 150 °C)
Power supply 13.5 to 42 VDC or 85 to 265 VAC
Response time 1 second 
Output Pulse and 4-20 mA
Communication RS485 or HART
Display Indication Mass flow, Volume flow in normal condition, Total flow, Temperature of
medium, Velocity
Signal output 4-20mA (std), Pulse (opt)
Protection IP65
Explosion Ex d II C T3 Gb (NEPSI) (Optional)
Structure Drawing

Supplier's popular products
Contact Supplier

We have more categories for you. lf you can't find the products you want above,just fill in the form and tell us whatproducts you want to import from China.

chat top