Saliva Alcohol Test Strip (Saliva)

Saliva Alcohol Test Strip (Saliva)

Specifications:

No need additional equipment
Room temperature storage

 

Detailed Product Description:

Saliva Alcohol Test Strip
1.formats:strip
2.specimens:saliva
3.read in 2min
4.accuracy:above 99.6%

 

One Step Saliva Alcohol Test Strip 

 

       One Step Alcohol Saliva Test Strip is intended for use as a rapid method to detect the presence of alcohol in saliva for blood alcohol concentration (BAC) greater than 0.02%. It has been published that the concentration of alcohol in saliva is almost equal to that in blood.  

 

Descriptions:

Product name Alcohol Saliva Test Strip Kits
Formats strip
Specification 5.0 mm
Sensivity 0.02g/dL
Accuracy 99%
Specimens saliva
Use selt-test, professional-test, home-test
Read Time 30seconds-2mins
Storage room temperature
Shelf Time 24-36months from the date of manufacture
Shipping By FedEx or By Air
Package one strip in one foil pouch
Deliever Time 5-30days depend on your order quantity and requirements

 

INTENDED USE
Rapid Saliva Alcohol Test Strip is intended for use as a rapid method to detect the presence of alcohol in saliva for blood alcohol concentration (BAC) greater than 0.02%. It has been published that the concentration of alcohol in saliva is almost equal to that in blood.

The rapid test is intended for the semi-quantization of ethyl alcohol in human saliva. To confirm the concentration of positive specimens, an alternate, non-enzymatic technology such as headspace gas chromatography should be used.

 

 
TEST PROCEDURE
1. Remove a strip from the foil pouch by tearing at the notch and place it on a level surface.
2. Saturate the reactive pad by dipping the reaction pad into the saliva specimen collected in a sputum cup, or by applying saliva directly to the reaction pad. After 10 seconds, shake off the excess saliva.
3. Immediately start timer and at 2 minutes, compare the reactive pad with the provided colored chart below.
INTERPRETATION OF RESULTS
Positive(+):
A distinct color developed all over the pad. The positive result indicates that the BAC is 0.02% or higher. The alcohol concentration are related to the colored chart above.
Negative (-):
Almost no color change by comparing with the background. The negative result indicates that the BAC is less than 0.02%.
Invalid:
The test should be considered invalid If only the edge of the reactive pad turned color that might be ascribed to insufficient sampling. The subject should be re-tested.
 
Some Detailed Photos
DSC_0124.JPGDSC_0127.JPGDSC_0182.JPG
 
Contact Supplier

We have more categories for you. lf you can't find the products you want above,just fill in the form and tell us whatproducts you want to import from China.

chat top