Products
Search
Categories
Electronics Product Beauty / Personal Care Furniture / Building Materials Automotive Machinery Clothing Accessories Home Department Store International Logistic Service
Contact Supplier
To: Annie Fu
Product description
Product Description

 

SAL Salbutamol Rapid Test Swine Urine

 

Company Introduction

We,Gemc Technology (Zhengzhou) Co.,Ltd,supply kinds of rapid test kits: fertility test kits (pregnancy test,ovulation test,menapause test),infectious disease test (hepatitis test,malaria test,chlamydia test,gonorrhea test,h.pylori test,toxoplasma test,dengue test, typhoid test...),tumor markers test (psa test,fob test,cea test,fob test),cardiac markers test (myoglobin test,tropponin I test,ck mb test), DOA drug of abuse test (mor,opi,mop,met,thc, mdma...), urinalysis reagent test strips (protein, glucose.....), alcohol test, vaginal ph test.

 

Introduction

 

The salbutamol test cassette is a lateral flow cassette test for rapid on-site or in-lab detection of residual salbutamol in urine,blood serum,and animal feed of livestock and poultry.

Assay sensitivity:10 ng/ml (10 ppb)

 

Principle

 

The salbutamol test cassette is based on the principle of colloidal gold immunochromatography.An anti-salbutamol antibody is conjugated to colloidal gold and placed on conjugate pad.Colloidal gold provides red color to visualize antibody-antigen binding. Salbutamol antigen is immobilized on nitrocellulose membrane.After test sample is loaded onto sample pad,it mixes with gold-antibody conjugate and migrates along the membrane.If the sample contains no salbutamol or amount of salbutamol lower than detection limit,antibody conjugated to colloidal gold will bind the antigen immobilized on membrane,leading to clear red color presented on membrane detection line where the test antigen is immobilized (as negative result).If salbutamol concentration is higher than detection limit in the test sample,it will bind gold-antibody conjugate and prevent its binding onto the antigen line on membrane. As a result,no color will be visible on detection line on membrane (indicating positive result).

 

Contents

 

l Test cassette

 

l Desiccant

 

l Dropper

 

l Manual

 

Precaution

 

  1. Open the package upon request to avoid the test cassette being damped.
  2. Use one cassette and one dropper for one test. Store the rest of the test cassette in dark at 8-250C environment and avoid being damped.
  3. Avoid touching the membrane in the cassette.
  4. Each package containing one test cassette and one drop is for one time use only. Please do not reuse.

Sample preparation

 

Urine:Use the urine sample directly and do not need to dilute (use urine sample which is back to room temperature)

 

Operation procedures

 

Collect approx. 20 ml of urine sample using a clean centrifuge tube or other suitable container. Sample needs to be frozen if immediate testing is not possible.Refrigeration is recommended for short-term storage, and care must be taken to avoid microbial growth or contamination.Centrifuge sample when precipitation or turbidity is visible,and supernatant is used as test solution.

water and mix well,followed by ultrasound treatment in 37 C ultrasonic water bath for 30 minutes (with mixing every 10 minutes).Equilibrate contents of the tube to room temperature,centrifuge at 4000 rpm for 5 minutes and collect supernatant as test solution.

Add 2 drops of test solution from a), b) or c) described above into sample loading well with a disposable dropper,and observe result in 8 to 15 minutes.

 

Test Result Interpretation

 

Test result is interpreted by observing test line and control line shown in result window.

 

Negative (-) both test and control lines are present,and test line is equal to or darker than control line. This indicates salbutamol concentration in sample is lower than 3 ng/ml;

 

Positive (+):

control line is present,and test line is either absent or lighter than control line.This result indicates salbutamol concentration is higher than 3 ng/ml in sample;

 

Invalid test:

no control line is present.Please repeat the test using a new test cassette

 

following instructions on this user guide.

 

 

five cassette sal kits.jpgfive sal cassette.jpg

Package & Storage

Package & Storage.jpg 

Payment & Delivery

Packing & Delivery 

Certifications

CE Certificates 

Our Services

1. Our service

 

Gemc are synonymous with quality, personalized service and a commitment to excellence.  With our specialized rapid, diagnostic test technologies, high quality assurance, brand recognition, innovative research and development techniques, customer-centric design, an experienced management team, and an energetic sales force, Gemc continues to set the standards in product quality and reliability.  We believe in continually improving our products and service, and making the business relationship a beneficial experience for both customers and employees.  

 

 

 Based on our core competence in rapid test technology, high quality assurance in products, international renowned brand name, innovative R&D, customer-centric product design as well as strong sales network, the experienced management team and energetic sales force of Gemc will lead our life to achieve peacefulness, harmony, and higher quality.

 

 

2. How to order our product

 

(1) Customers to contact to consult , and purchase our products

(2) Our trader make a perfessional form according to your product

(3) Inform the product you need after you confirmation of the product

FAQ

Q1: What's the method u use to do the test?
A: Colloidal Gold Method.


Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.


Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.


Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.
 
Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.


Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:Technical data: Such as the accuracy, specificity and sensitivity.
Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.

Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.

Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice

Contact us

Telephone: 86-371-60997506  

             Fax: 86-371-60997506

     Website: http://www.gv-medic.com
    Address: NO.20,Bosong Road, Zhengzhou, Henan ,China

              Zip: 450001
            City: Zhengzhou

    Country: China (Mainland)

Electric Golf Cart
Inquiry