Application:
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.
Features:
- 15” TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.
- Air compressor runs stably with low noise, creates quiet environment for doctors and patients.
- Integration breathing circuit design.
- Multiple working modes such as volume control and pressure limit.
- Multiple parameters monitoring interface to show clear parameter to the operator, allow operator know the patient conditions in all aspects.
- Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision O2 concentration detection function included.
- Electrical PEEP control.
- Breathing valve is disassembly and can be disinfected.
Safety:
- Three levels alarm system, visual and sound alarm information.
- With multiple type of alarms, reminding and protection functions.
- Self-check before running, eliminate system mulfuction.
- Advanced power management control technology.
- With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.
- Separate design of electric and gas, keep safety running of ventilator.
Specifications:
Ventilation modes: |
PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, IPPV, A/C, PCV, PSV, SPONT/CPAP, SIGH, MANUAL |
Ventilator parameter ranges |
|
Tidal volume(Vt) |
0 ~ 2000mL |
Frequency (Freq) Oxygen concentration |
1bpm ~ 100 bpm 21%-100% |
I/E |
4:1~1:8 |
PEEP |
0cmH2O ~ 40 cmH2O |
Pressure Limit |
20 cmH2O ~ 100 cmH2O |
Monitored Parameters |
|
Frequency (Freq) |
0 /min ~ 100 /min |
Tidal volume(Vt) |
0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing |
0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O |
Oxygen concentration |
15 % ~ 100 % |
Oxygen supply |
2 mins automatic |
Inspiration hold |
|
Expiration hold |
|
Nebulizer (atomization) |
automatic |
|
|
Oscillographs display: |
|
P-T(pressure – time) |
|
F-T(flow – time) |
|
P-V loop (pressure – volume loop) |
|
V-T(volume – time ) |
|
F-V Loop(Flow-Volume Loop) |
|
P-F Loop(Pressure-Flow Loop) |
|
Alarms and protection |
|
The AC power failure alarm |
Power failure or no connection |
Internal battery backup low voltage alarm |
≤11.3±0.3V |
No tidal volume |
No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm |
5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm |
20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm |
(PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit |
5-60s Show on screen Show on screen |
The maximum limited pressure |
<12.5 kPa |
|
|
Working conditions |
|
Gas source |
O2, AIR |
Pressure |
280kPa-600kPa |
Voltage |
~220V±22V |
Power frequency |
50Hz ± 1Hz |
Input power |
900VA (with air compressor) 250VA (without air compressor) |