Products
Search
Categories
Electronics Product Beauty / Personal Care Furniture / Building Materials Automotive Machinery Clothing Accessories Home Department Store International Logistic Service
Contact Supplier
To: Annie Fu

Rapid HIV 1 2 test diagnostic Kits (Blood serum/plasma)

Product description
Product Description

Rapid HIV 1 2 test diagnostic Kits (Blood serum/plasma)

One Step Cassette Style AntiHIV 1+2 Test is a rapid direct binding screening test for the presence of antibodies to HIV 1 and HIV 2 viruses.  The test is based on the principle of double antigen sandwich immunoassay for detection of Anti-HIV in serum. Purified recombinant antigens are employed to identify AntiHIV specifically.  This one step test is very sensitive and only takes about 10-20 minutes.  Test results are read visually without any instrumentation.


Specimen Collection 
For serum, collect blood into a container without anticoagulant.  Allow the blood to clot and separate the serum from the clot.  Use the serum for testing. 
If the specimen cannot be tested on the day of collection, store the serum specimen in a refrigerator or freezer.  Bring the specimens to room temperature before testing.  Do not freeze and thaw the specimen repeatedly.

Test Procedure
1. To begin testing; open the sealed pouch by tearing along the notch.. Remove the test from the pouch.
2.Immerse the strip into the sample with the arrow end pointing towards the sample. Do not immerse past the MAX (maximum) line. Take the strip out after 8-10 seconds and lay the strip flat on a clean, dry, nonabsorbent surface 
3. Wait 10-15minutes and read result. Do not read results after 20 minutes.

Interpretation of result
Negative:Only one colored band appears on the control (C) region.No apparent band on the test (T) region.
Positive:In addition to a pink coloured control (C) band, a distinct pink colored band will also appear in the test (T) region.
Invalid:A total absence of color in both regions is an indication of procedure error and/or the test reagent has deteriorated.

Storage and Stability
The test kit should be stored at room temperature (18 to 30°C) in the sealed pouch to the date of expiration. The test kits should be kept away from direct sunlight, moisture and heat.

 Precautions
1,For in vitro diagnostic use only.
2,Do not use test kit beyond expiry date.
3,The test device should not be reused.
4,For samples that test positive by the One Step ANTI-HIV Test, a more specific confirmatory test should be done.  A clinical evaluation of the patient's situation and history should also be made before a final diagnosis is established.  The use of a rapid test is not sufficient to diagnose AIDS even if antibodies are present.  Also, a negative result does not preclude the possibility of infection with HIV.
5,The instructions for use and reading of the test must be followed exactly in order for the test to perform properly. 

Detailed Images
Package & Storage
Payment & Delivery
Certifications
Our service

1.Our serveces

GEMC is the short name of Gem Medic Electric & Technology Co.,Ltd located in Henan Province, China, which is a privately-held corporation high-tech enterprise specializing in trade of rapid medic diagnostic test kits and device. The main products we supply are pregnancy test kits, ovulation test kits, sperm fertility test, drug of abuse test, infectious disease test, saliva alcohol tester, digital clinical thermometer, blood pressure monitor,ovulation microscope monitor and other medical test device.

Since the foundation of company, based on the belief-product quality and service are the lifeline of enterprise, so now we have had global customers from all of over the world, such as France, Russia, UAE, Brazil, Mexico, Peru and south Africa, totally more than 70 countries and areas.

And we will sincerly hope supply more & better service for you, 'for your better health & happy life' is our working target, welcome to visit our website to know more about it, thanks.

2. How to order our product

(1) Customers to contact to consult , and purchase our products

(2) Our trader make a perfessional form according to your product

(3) Inform the product you need after you confirmation of the product

FAQ

Q1: What's the method u use to do the test?

A: Colloidal Gold Method.


Q2: What's ur MOQ ?

A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.


Q3: What's ur packing of the tests?

A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.


Q4: What's the main differences when comparing products from different suppliers?

A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.


Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?

A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.


Q6: How can i distinguish a good test kit?

A: U can judge from the 4facts:Technical data: Such as the accuracy, specificity and sensitivity.

Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.

Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.

Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice

Contact Us

Telephone: 86-371-60997506
Fax: 86-371-60997506
Website: http://www.gv-medic.com
Address: NO.20,Bosong Road, Zhengzhou, Henan ,China
Zip: 450001
City: Zhengzhou
Country: China (Mainland)

Electric Golf Cart
Inquiry Whatsapp: +44 7522 566048