Rated system voltage 12V/24V/48V/96V/110V/120V/192V/220V/240V VDC
Rated charge current 50A/100A/150A/200A
Rated discharge current 50A (customizable)
Note:Customizable lithium battery parameters
Rated system nominal voltage |
240V |
220V |
192V |
120V |
110V |
96V |
48V |
24V |
12V |
|
Overvoltage disconnection voltage (OVD) |
320V |
293V |
256V |
160V |
147V |
128V |
64V |
32V |
16V |
|
Overvoltage disconnection recovery voltage(OVD-R)) |
300V |
275V |
253V |
248V |
127V |
111V |
56V |
28V |
14V |
|
Balanced voltage(ECV) |
294V |
270V |
235V |
147V |
135V |
118V |
59V |
29V |
14.7V |
|
Improve voltage(BCV) |
288V |
264V |
230V |
144V |
132V |
115V |
57.6V |
28.8V |
14.4 |
|
Float charge voltage(float) |
276V |
253V |
221V |
138V |
127V |
110V |
55.2V |
27.6V |
13.8 |
|
Under voltage disconnect(under) |
216V |
198V |
173V |
108V |
99V |
86.4V |
43.2V |
21.7V |
10.8 |
|
Undervoltage recovery (under-R) |
250V |
229V |
200V |
125V |
115V |
100V |
50V |
25V |
12.5 |
|
Duration of equilibrium |
2hours |
|
|
|||||||
Duration og increase |
2hours |
|
|
|||||||
|
|
|
Electrical Parameters |
||||||||||
Electrical parameter description |
Specific parameters |
Remarks |
||||||||
Rated system nominal voltage |
240V |
220V |
192V |
120V |
110V |
96V |
48V |
24V |
12V |
|
Maximum charging current(*N) |
50A |
50A |
50A |
50A |
50A |
50A |
50A |
50A |
50A |
N=1/2/3/4 |
Maximum PV input power(*N) |
12000W |
11000W |
9600W |
6000W |
5500W |
4800W |
2400W |
1200W |
600W |
|
Battery terminal maximum allowable voltage |
320V |
293V |
256V |
160V |
147V |
128V |
64V |
32V |
16V |
|
Maximun PV Open circuit voltage |
430V |
430V |
400V |
250V |
230V |
200V |
100V |
50V |
25V |
|
Minimum PV operating voltage |
300V |
275V |
240V |
150V |
138V |
120V |
60V |
30V |
15V |
|
Static loss* |
<0.2A |
|
||||||||
Charging circuit voltage drop |
≤0.5V |
|
||||||||
Discharge loop voltage drop |
≤0.3V |
|
||||||||
Battery terminal control parameters(Temperature:25℃)(Factory default data) |
Environmental parameters |
|
Work temperature |
-35℃-+55℃ |
Store temperature |
-35℃-+80℃ |
Hunidity range |
10%-90%, No condensation |
Protection level |
IP30 |
Using altitude |
≤3000 meter(More than derating) |
Mechanical parameters |
|
Dimension |
432*280*131.6(mm) |
Terminals |
24mm2 |
Net weight |
7.8kg |