Original SICK KT6W-2N5116 10 mm LED Color mark Sensor, Contrast Sensor
Keywords:
Keywords:
Original SICK KT6W-2N5116 10 mm LED Color mark Sensors, Contrast Sensors
KT6W-2N5116 color mark sensor is widely use in the Printing machine , bag making machine , slitting machine and lamination machine
FEATURES
· Sensing distance: 10 mm
· Light spot size: 1.2 mm x 4.2 mm
· Switching frequency: 10 kHz
· Type of light: RGB
· Connection type: Male connector M12, 5-pin
· Adjustment: Static 2-point teach-in
· Communication interface: -
Dimensions (W x H x D) |
30.4 mm x 53 mm x 80 mm |
Sensing distance |
10 mm |
Housing design (light emission) |
Rectangular |
Sensing distance tolerance |
± 3 mm |
Light source |
LED, RGB 2) |
Wave length |
470 nm, 525 nm, 640 nm |
Light emission |
Long and short side of housing, exchangeable |
Light spot size |
1.2mm x 4.2 mm |
Light spot direction |
Vertical 3) |
Adjustment |
Teach-in button |
Teach-in mode |
Static 2-point teach-in |
1) From front edge of lens.
|
|
2) Average service life: 100,000 h at TU = +25 °C.
|
|
3) In relation to long side of housing. |
MECHANICS/ELECTRONICS
Supply voltage |
10 V DC ... 30 V DC 1) |
Ripple |
≤ 5 Vpp 2) |
Power consumption |
<800 mA 3) |
Switching frequency |
10 kHz 4) |
Response time |
50 µs |
Output type |
NPN |
Switching output (voltage) |
NPN: HIGH = approx. VS / LOW ≤ 2 V |
Output current Imax. |
100 mA |
Retention time (ET) |
25 ms, non-volatile memory |
Connection type |
Male connector M12, 4-pin |
Protection class |
II 5) |
Circuit protection |
UV connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression |
Enclosure rating |
IP 67 |
Weight |
400 g |
Housing material |
Zinc diecast |
1) Limit values when operated in short-circuit protected network: max. 8 A.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) With light/dark ratio 1:1.
5) Signal transit time with resistive load.
6) Short-circuit protected.
7) Reference voltage DC 50 V.
AMBIENT DATA
Ambient operating temperature |
–10 °C ... +55 °C |
Ambient storage temperature |
–25 °C ... +75 °C |
Shock load |
According to IEC 60068 |