Product parameters

Product Details
Product Description

Features:

  1. Fast to test and easy to read
  2. Read results within 5 minutes
  3. High sensitivity and high quality

Specification

Method

Lateral flow test

Format

strip/cassette/urine cup/multi-panel

Accuracy

> 92.2%

Precision

>95%

Specimen

urine

Read time

2-5 minutes

Storage

Room temperature

Shelf life

24 months from date of manufacture

Intended Use

For the detection of  drug abuse test

 

Name of available drugs to be test list

Diagnostic Rapid Test Name/SpecimentsFormatsizesensitivity
AMP One Step Amphetamine Test(Urine) strip3.0mm500ng/ml 
cassette5.0mm
BAR One Step Barbiturates Test(Urine)strip3.0mm300ng/ml 
cassette5.0mm
BZO One Step Benzodiazepines Test(Urine) strip3.0mm300ng/ml 
cassette5.0mm
COC One Step Cocaine Test(Urine) strip3.0mm300ng/ml 
cassette5.0mm
MET One Step Methamphetamine Test(Urine) strip3.0mm1000ng/ml 
cassette5.0mm
MDMA One Step Ecstasy Test (Urine)strip3.0mm500ng/ml 
cassette5.0mm
MOR One Step Morphine Test Strip (Urine)strip3.0mm300ng/ml 
cassette5.0mm
MTD One Step Methadone Test Strip (Urine) strip3.0mm300ng/ml 
cassette5.0mm
OPI One Step Opiate Test Strip (Urine)strip3.0mm2000ng/ml 
cassette5.0mm
PCP One Step Phencyclidine Test (Urine)strip3.0mm25ng/ml 
cassette5.0mm
TCA One Step Tricyclic Antidepressants Test (Urine) strip3.0mm1000ng/ml 
cassette5.0mm
THC One Step Marijuana Test (Urine) strip3.0mm50ng/ml 
cassette5.0mm
Multi-Drug test (Urine)2 in 1 test panel5.0mm 
3 in 1 test panel5.0mm 
4 in 1 test panel5.0mm 
5 in 1 test panel5.0mm 
6 in 1 test panel5.0mm 
10 in 1 test panel5.0mm 
Multi-Drug  test cup (Urine) 5 in 1 test cup5.0mm 
6 in  1 test cupred cap 
blue cap 
Multi-Drug test 6 in 1 (Saliva)panel  
cup  

 

How to use the One Step Urine (Multi) Drug (Screen) Test (kit)?

[For Strip]

Remove the test strip from the sealed pouch and use it as soon as possible.

  1. Immerse the strip vertically into the urine specimen with the arrow end pointing towards the urine. Do not immerse the strip past the Max Line. See the illustration below.
  2. Remove the strip after 10 seconds and lay the strip flat on a clean, dry, non-absorbent surface, and then begin timing.
  3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes

418741078_855.jpg

[For Cassette]

  1. Remove the test cassette from the sealed pouch.
  2. Hold the dropper vertically and transfer 3 full drops (approx. 100ml) of urine to the specimen well of the test cassette, and then begin timing. See the illustration below.
  3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes.

PCP.jpg

For Dipcard]

  • Remove the test card from the sealed pouch and use it as soon as possible.
  • Remove the cap from the end of the test card. Immerse the strip(s) of the test card vertically in the urine specimen with arrows pointing toward the urine specimen. Immerse the test card to at least the level of the wavy lines on the strip(s), but not above the arrow(s) on the test card. See the illustration below.
  • Remove the test card after 10 seconds and lay the card flat on a non-absorbent surface, and then begin timing.
  • Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 mins

multi drug screen description.jpg

For Multi-Drug Screen Test Cup]

  1. Remove the test cup from the sealed pouch and use it as soon as possible.
  2. Donor provides specimen and secures the cap by pressing down on all three corners.
  3. On a flat surface, technician pushes key to a fully closed position.
  4. Peel off the label on the multi-drug test card to view results. The test is read in the reaction well.
  5. Start the timer and wait for colored lines to appear. Interpret the test results at 3-5 minutes. Results remain stable for up to sixty minutes. See the illustration below. For detailed operation instructions, please refer to the Procedure Card

418743270_518.jpg

 

Results Interpretation: Negative or Positive Indication

 

Negative:Two lines appear. One red line should be in the control region (C), and another apparent red or pink line adjacent should be in the test region (T). This negative result indicates that the drug concentration is below the detectable level. (*Note: The shade of red in the test line region (T) will vary, but it should be considered negative whenever there is even a faint pink line.)

 

Positive:One red line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the drug concentration is above the detectable level.

 

Invalid:Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test panel. If the problem persists, discontinue using the lot immediately and contact your local distributor

 

Lists of Common used (Multi) Drug:

  • Amphetamine(AMP);
  • Barbiturates(BAR);
  • Benzodiazepines (BZO);
  • Buprenorphine (BUP);
  • Cocaine (COC);
  • Ketamine (KET);
  • Marijuana (THC);
  • Methadone (MTD);
  • Methamphetamine (mAMP);
  • Methylenedioxymethamphetamine (MDMA);
  • Morphine (MOP);
  • Opiates (OPI);
  • Oxycodone (OXY);
  • Phencyclidine (PCP);
  • Propoxyphene (PPX);
  • Tricyclic Antidepressants (TCA);