Olyair room air conditioner 18000btu cool and heat for the German market
Wall Split Air Conditioner Specification Sheet
Model | OS-24HRFN1 | ||
Power supply | Ph-V-Hz | 220-240V~ 50Hz, 1Ph | |
Rated Cooling | Capacity | Btu/h | 22000(7240~24640) |
Cooling Power input | W | 171~2780 | |
Cooling Current | A | 0.74~12.09 | |
Rated Heating | Capacity | Btu/h | 25000(4600~30000) |
Heating Power input | W | 235~3140 | |
Heating Current | A | 1.02~13.65 | |
Seasonal Cooling | Pdesignc | kW | 6.4 |
SEER | W/W | 6.1 | |
Energy Efficiency Class | A++ | ||
Heating(Average ) | Pdesignh | kW | 5.2 |
SCOP | W/W | 4.0 | |
Energy Efficiency Class | A+ | ||
Tbiv | ℃ | -7 | |
Heating(Warmer ) | Pdesignh | kW | 7.1 |
SCOP | W/W | 4.8 | |
Energy Efficiency Class | A++ | ||
Tbiv | ℃ | 5 | |
Tol | ℃ | -15 | |
Moisture Removal | L/h | 2.3 | |
Max. input consumption | W | 3100 | |
Max. current | A | 14.5 | |
Starting current | A | ---- | |
Compressor | Model | DA150S1C-20FZ | |
Type | Twin-rotary | ||
Brand | TOSHIBA | ||
Capacity | Btu/h | 15286 | |
Input | W | 1150 | |
Rated current(RLA) | A | 9.7 | |
Locked rotor Amp(LRA) | A | ---- | |
Thermal protector | KSD301 | ||
Thermal protector position | EXTERNAL | ||
Capacitor | uF | --- | |
Refrigerant oil/oil charge | ml | ESTER OIL VG74/500 | |
Indoor fan motor | Model | WZDK58-38G | |
Brand | Shibaura | ||
Output | W | 58 | |
Capacitor | uF | - - | |
Speed(Hi/Mi/Lo) | r/min | 1180 / 1100 / 900 | |
Indoor coil | a.Number of rows | 2 | |
b.Tube pitch(a)x row pitch(b) | mm | 21x13.37 | |
c.Fin spacing | mm | 1.3 | |
d.Fin type (code) | Hydrophilic aluminum | ||
e.Tube outside dia.and type | mm | Φ7, inner grooved tube | |
f.Coil length x height x width | mm | 780x336x26.74 | |
g.Number of circuits | 4 | ||
Indoor air flow (Hi/Mi/Lo) | m3/h | 1150/1070/880 | |
Indoor sound pressure level (Hi/Mi/Lo) | dB(A) | 49/43/36 | |
Indoor sound power level (Hi) | dB(A) | 62 | |
Indoor unit | Dimension(W*D*H) | mm | 1045x235x315 |
Packing (W*D*H) | mm | 1135x395x315 | |
Net/Gross weight | Kg | 12/15.2 | |
Outdoor fan motor | Model | WZDK50-38G | |
Brand | Shibaura | ||
Output | W | 50 | |
Capacitor | uF | - - | |
Speed | r/min | 800 | |
Outdoor coil | a.Number of rows | 2 | |
b.Tube pitch(a)x row pitch(b) | mm | 25.4x22 | |
c.Fin spacing | mm | 1.4 | |
d.Fin type (code) | Hydrophilic aluminium | ||
e.Tube outside dia.and type | mm | Φ9.52,innergroove tube | |
f.Coil length x height x width | mm | 766x660x44 | |
g.Number of circuits | 4 | ||
Outdoor air flow | m3/h | 2700 | |
Outdoor sound pressure level | dB(A) | 60 | |
Outdoor sound power level | dB(A) | 67 | |
Outdoor unit | Dimension(W*D*H) | mm | 845x320x700 |
Packing (W*D*H) | mm | 965x395x755 | |
Net/Gross weight | Kg | 47 / 50 | |
Refrigerant | Type | R410A | |
GWP | 1975 | ||
Charged quantity | Kg | 1.95 | |
Design pressure | MPa | 4.2/1.5 | |
Refrigerant piping | Liquid side/ Gas side | mm(inch) | Φ9.52/Φ15.9(3/8"/5/8") |
Max. refrigerant pipe length | m | 30 | |
Max. difference in level | m | 20 | |
Connection wiring | 2.5(Optional) | ||
Plug type | -- | ||
Thermostat type | Remote Control | ||
Operation temperature | Indoor(cooling/ heating) | ℃ | 17~32/0~30 |
Outdoor(cooling/heating) | ℃ | -15~50/-15~30 | |
Application area | m2 | 32-53 | |
Qty’per 20’ /40’ /40'HQ | 69/140/160 |
Features:
On the basis of low noise air duct system and quiet design, you can shut off the AC beep and display by pressing mute operation to create a super-quiet environment.
Apart from the conventional remote control, Aurora split provides a variety of optional, including wired control, front desk control, and central control.
Optional functions: (If you need below add functions, please let me know)
1. Active carbon Filter
2. Photocatalyst Filter
3. Catechin Filter
4. Vitamin-enriching Filter
5. Nano Silver Filter
6. Air Ionizer
Wall Split Packing
Window Packing Carton:
Floor Standing Packing:
1. Why the heating of the air conditioner does not function?
Answer: Our remote control is designed to have both ‘cooling only’ mold and ‘cooling & heating’ mold. Users need to activate either the ‘cooling only’ mold or the ‘cooling & heating’ mold. If ‘cooling only’ mode is activated, the heating function of the air conditioner will not work, it will starting heating up the room temperature only when you turn it into a ‘cooling & heating’ mold. The way of setting is demonstrated in detail in the user’s manual.
2. Why the air conditioner does not blow out hot air until several minutes after it is activated?
Answer: This is because when the heating mold just started, the temperature of the evaporator is relatively low and the wind blow out would be cool. Therefore, there has designed a function of cool air protection, which will stop the indoor fan from working until the evaporator reaches the set temperature. Thus, there will not be any wind blow out at the beginning.
3. Why the air conditioner does not work for the first 3 minutes, after it is restarted after a sudden power lost?
Answer: This is because our air conditioning has been set up with the power lost memory function (AUTO - RESTART), when suddenly power off and then immediately power on, the air conditioner will operate according to the same setting before the power off. Therefore, in order to prevent the impact of the imbalance system to the compressor on its startup, the compressor will re-start operating 3 minutes delay. Thus, the condition will not either heat up or cool down the room temperature in these 3 minutes.
4. Why the capacity of the new air condition seemed not strong enough to cool down the room temperature?
Answer: There could be various reasons:
1) The capacity is insufficient, professional will be necessary for checking.
2) Wrong model of an air conditioner is brought, as the choice of models has a direct relationship with the following conditions:
A. The area of the room.
B. The cooling load of the room. It is related to the heat leakage, which is affected by the thermal insulation of the room wall, large glass window, and no. of heating source such as high voltage home appliances. The heat leakage will also be affected in places such as the dining room and living room.
To our experience, the capacity of air conditioner = room area X cooling load, the cooling load can be between 160 to 220, depending on the heat leakage. For example, if there are not any large voltage home appliances and the thermal insulation is ok, the cooling load of a single room can be estimated as 160, and 170 for a double room, 200 for a living room, and 220 for a dining room. Commercial areas should be estimated according to real situations.
Welcome to contact our service team for your project on the air conditioner business. We count to be your wise supplier!