Products
Search
Categories
Electronics Product Beauty / Personal Care Furniture / Building Materials Automotive Machinery Clothing Accessories Home Department Store International Logistic Service
Contact Supplier
To: Annie Fu

OlyAir Horizontal Expose Fan coil unit, hot water fan coil unit, chilled water fan coil unit

Product parameters

Product Details
Product Description

 

Introduction of OlyAir Fan Coil Unit

 

The OlyAir Chilled Water Fan Coil Unit is designed and manufactured on the base of advanced technology, and utilize qualified galvanized iron as structure material. Due to its super-thin design,  it has such advantages:  beautiful outlook,  space-saving,  easy installation,  etc.  And the most obvious advantage is that it can decrease the outlet air temperature difference as low as possible to make the room more comfortable, as well as don’t decrease cooling capacity output. For the large airflow volume design,  it can increase room ventilation frequency,  supply more fresh air, and balance room temperature distribution. Benefiting from the adoption of advanced material and technology, it can effectively reduce the running noise and keep running smoothly.  With the advantages above,  it can be widely applied in the market, hospital, office building, hotel airport, etc..

 

 

Features: 

 

Coling capacity: 1.8KW to 11.9KW(6143btu-43004btu);

Heating capacity: 2.2KW to 18.9KW(9215-64506btu);

1) Compact structure design with a thickness of 260mm only to save space;
2) Airflow maybe 340 to 2380 stere per hour;
3) Low noise with stable running; 
4) The motor can be dismantled from the return outlet for maintains at the season changing period;
5) Fresh air intake can be pre-made in return air box;
6) Condensed water tray can be extended, if required, to ensure collecting the water and it can be made of stainless steel or galvanization steel plate;
7) Four-pipe type is available for consideration;

 

 

Specs:

 

Model LC~ 34HE 51HE 68HE 85HE 102HE 136HE 170HE 204HE 238HE
Air flow
 (m3/h)
High speed 340 510 680 850 1020 1360 1700 2040 2380
Medium speed 255 383 510 638 765 1020 1275 1530 1785
Low speed 170 255 340 425 510 680 850 1020 1190
Cooling capacity High W 1800 2700 3600 4500 5400 7200 9000 10800 12600
BTU 6143 9215 12287 15359 18430 24574 30717 36860 43004
Medium W 1620 2440 3290 4120 4850 6550 8190 9730 11580
BTU 5529 8328 11229 14062 16553 22355 27952 33208 39523
Low W 1310 2010 2650 3320 3900 5300 6610 7860 9350
BTU 4471 6860 9044 11331 13311 18089 22560 26826 31912
Heating capacity High W 2700 4050 5400 6750 8100 10800 13500 16200 18900
BTU 9215 13823 18430 23038 27645 36860 46076 55291 64506
Medium W 2350 3520 4530 6040 6850 9260 11740 14140 16360
BTU 8021 12014 15461 20615 23379 31604 40069 48260 55837
Low W 1620 2470 3130 4170 4740 6500 8180 9710 11290
BTU 5529 8430 10683 14232 16178 22185 27918 33140 38533
Cooling water temperature 7-12℃
Hot water temperature 40-60℃
Power supply AC220V/50Hz
Heat Exchanger Type copper pipes covered into aluminum fins, fin pitch 2.2mm
Water supply kg/h 324 482 655 814 936 1278 1602 1915 2178
Water resistance kPa 30 30 30 30 40 40 40 40 50
Working pressure 1.6MPa
Low static pressure FCU Input power w 37 52 62 76 96 134 152 189 228
Motor power w 10 16 20 25 30 20×2 25×2 30×2 40×2
High static
pressure FCU
Static pressrue
30Pa
Input power w 44 59 72 87 108 156 174 212 253
Motor power w 12 20 25 30 40 25×2 30×2 40×2 50×2
Static pressure
50Pa
Input power w 49 66 84 100 118 174 210 250 300
Motor power w 16 25 30 40 50 30×2 40×2 50×2 60×2
Fan motor quantity 1 2 2 2 2 3 4 4 4
Noise
dB(A)
Low static pressure ≤37 ≤39 ≤41 ≤43 ≤45 ≤46 ≤48 ≤50 ≤52
High static pressure 30Pa ≤40 ≤42 ≤44 ≤46 ≤47 ≤48 ≤50 ≤52 ≤54
High static pressure 50Pa ≤42 ≤44 ≤46 ≤47 ≤49 ≤50 ≤52 ≤54 ≤56
Pipe  Inlet/outlet water pipe 3/4 "internal thread
Condensation water pipe 3/4" external thread
Dimension L mm 900 900 1110 1150 1290 1520 1740 1950 2140
W mm 520 520 520 520 520 520 520 520 520
H mm 285 285 285 285 285 285 285 285 285
20GP container loading quantity 247  247  201  194  173  146  128  114  104 
40GP container loading quantity 487  487  395  381  340  289  252  225  205 

 

 

Note: 

 

1. Cooling: Indoors DB 27℃, WB 19.5℃; Chilled water inlet/outlet temp. 12℃/7℃.                      
2. Heating: Indoors DB WB 21°C, heating water inlet&outlet temperature  60°C/50°C;                      
3.The noise level based on: background noise 11.5Db(A) semi-anechoic room.                      
4. Water resitance refers to that of rated water flow volume;                      
5. Input power refers to that of High speed air flow;                      
6. Above parameters are for your reference to model choice of FCU with cooling and heating; Heating energy of one row is 40% of three rows';   Low                       
static pressure air flow volume loss: 10%, high static pressure air flow volume loss: 20%.                      

 

 

 

 

Below is some other model of horizontal concealed Fan coil unit: 

 

Install of horizontal concealed Fan Coil Unit 

 

.jpg

 

 

 

With Return box and side air return 

 

  .jpg

 

 

Horizontal concealed with down return air 

 

 .jpg

 

 

 

 .jpg

 

 

Horizontal concealed without return box 

 

  .jpg

 

 

 

 .jpg.jpg

 

 

 

Mechanical control or remote control, wire control optional. 

 

 

Some local shoot picture of our concealed fan coil unit 

 

IMG_7529.JPGIMG_7535.JPGIMG_7546.JPGIMG_7551.JPG

 

 

 Welcome to contact us for a price ! 

 

Electric Golf Cart
Inquiry Whatsapp: +44 7522 566048