Products
Search
Categories
Electronics Product Beauty / Personal Care Furniture / Building Materials Automotive Machinery Clothing Accessories Home Department Store International Logistic Service
Contact Supplier
To: Annie Fu

Home or Enterprise used Multi Drug Test Cassette kit (CE&ISO13485)

Product parameters

Product Details
Product Description
Product Description

 

Specifications

 

1.multi drug test cassette 
2.Specimen:Urine 
3.15 Common Drugs 
4.Cassette format & easy testing 
5.CE&ISO13485 approved 

 

 1. Lists of Common abused (Multi) Drugs:

  • Amphetamine(AMP); 
  • Barbiturates(BAR);
  • Benzodiazepines (BZO);
  • Buprenorphine (BUP);
  • Cocaine (COC);
  • Ketamine (KET);
  • Marijuana (THC);
  • Methadone (MTD);
  • Methamphetamine (mAMP);
  • Methylenedioxymethamphetamine (MDMA);
  • Morphine (MOP);
  • Opiates (OPI);
  • Oxycodone (OXY);
  • Phencyclidine (PCP);
  • Propoxyphene (PPX);
  • Tricyclic Antidepressants (TCA);

 2. Cut-off levels of Multi Drug (Urine Screening) Test cassette (kit):

The Multi panel Urine Drug Test is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs or drug metabolites in urine at the following cut-off concentrations:

Multi Drug test Cassette Make-ups

Specimen &Cut-off

Amphetamine (AMP) drug test

Urine &1,000ng/ml

Barbiturates (BAR)drug test

Urine &300ng/ml

Benzodiazepines (BZO)  drug test

Urine &300ng/ml

Buprenorphine (BUP)  drug test

Urine &10ng/ml

Cocaine (COC)  drug test

Urine &300ng/ml

Ketamine (KET)  drug test

Urine &1,000ng/ml

Marijuana (THC)  drug test

Urine &50ng/ml

Methadone (MTD) drug test

Urine &300ng/ml

Methamphetamine (mAMP) drug test

Urine &1,000ng/ml

Methylenedioxymethamphetamine (MDMA) drug test

Urine &500ng/ml

Morphine (MOP 300) drug test drug test

Urine &300ng/ml

Opiates (OPI 2000) drug test

Urine &2,000ng/ml

Oxycodone (OXY) drug test

Urine &100ng/ml

Phencyclidine (PCP) drug test

Urine &25ng/ml

Tricyclic Antidepressants (TCA) drug test

Urine &1,000ng/ml

 

3. How to use the One Step Urine Multi Panel Drug (Urine Screen) Test (kit)? 

[For Multi Drug Test Cassette] 

  1. Remove the test cassette from the sealed pouch.
  2. Hold the dropper vertically and transfer 3 full drops (approx. 100ml) of urine to the specimen well of the test cassette, and then begin timing. See the illustration below.
  3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes.

 .jpg

 

 

 

 

4. Results Interpretation: Negative or Positive Indication

Negative:

Two lines appear. One red line should be in the control region (C), and another apparent red or pink line adjacent should be in the test region (T). This negative result indicates that the drug concentration is below the detectable level. (*Note: The shade of red in the test line region (T) will vary, but it should be considered negative whenever there is even a faint pink line.)

 

Positive:

One red line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the drug concentration is above the detectable level.

 

Invalid:

Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test panel. If the problem persists, discontinue using the lot immediately and contact your local distributor.

 

Detailed images

 drug test kit _0100.JPGdrug test kit _0335.JPGdrug test kit 6-3.JPGdrug test kit 0121.JPGmuiti drug.jpgmulti drug.jpg

Package & Storage

Package & Storage.jpg 

Payment & Delivery

Packing & Delivery 

Certifications

CE Certificates 

Our Services

1. Our service

 

Gemc are synonymous with quality, personalized service and a commitment to excellence.  With our specialized rapid, diagnostic test technologies, high quality assurance, brand recognition, innovative research and development techniques, customer-centric design, an experienced management team, and an energetic sales force, Gemc continues to set the standards in product quality and reliability.  We believe in continually improving our products and service, and making the business relationship a beneficial experience for both customers and employees.  

 

 

 Based on our core competence in rapid test technology, high quality assurance in products, international renowned brand name, innovative R&D, customer-centric product design as well as strong sales network, the experienced management team and energetic sales force of Gemc will lead our life to achieve peacefulness, harmony, and higher quality.

 

 

2. How to order our product

 

(1) Customers to contact to consult , and purchase our products

(2) Our trader make a perfessional form according to your product

(3) Inform the product you need after you confirmation of the product

FAQ

Q1: What's the method u use to do the test?
A: Colloidal Gold Method.


Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.


Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.


Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.
 
Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.


Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:Technical data: Such as the accuracy, specificity and sensitivity.
Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.

Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.

Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice

Contact us

Telephone: 86-371-60997506  

             Fax: 86-371-60997506

     Website: http://www.gv-medic.com
    Address: NO.20,Bosong Road, Zhengzhou, Henan ,China

              Zip: 450001
            City: Zhengzhou

    Country: China (Mainland)