Products
Search
Categories
Electronics Product Beauty / Personal Care Furniture / Building Materials Automotive Machinery Clothing Accessories Home Department Store International Logistic Service
Contact Supplier
To: Annie Fu

HIV-P01 gemc High Sensitivity Rapid HIV Test Kits Antibody In Good Price

Product description
Product Description

Product principle

AIDS is an infectious disease caused by HIV virus. HIV 1/2 diagnostic reagents detect HIV 1/2 antibody in whole blood/serum/plasma
using highly specific antibody-antigen for reaction.If the sample to be tested contains HIV antibodies .HIV antibodies react with
gold-labeled antigens into complex Ab-Ag-Au. Under the effect of chromatography.The reactive complex moves forward to the
detecting area along the nitrocellulose membrane ans forms Ab-Ag-Au complex when is captured by antigens. And finally form a red
reaction line in the detecting area.

♣Introduction:
The one step HIV test is a rapid test based on the principle of immunoassay combined with conjugated colloid gold technology.The
HIV test (Serum/Plasma) is a diagnostic device to detect the presence of the anti-HIV in whole blood.
♣ Storage&Stability:
The test kit can be stored at temperatures from 4°C to 30°c in the sealed pouch up to date ofexpiration.The test kit should be
kept away from direct sunlight and moisture.Do not freeze the test kit.
♣ Specimen Collection:Blood should be collected aseptically into a clean tube without anticoagulants.Separate the serum or plasma

Test Procedure:1. Allow the test kit, specimen,and/or controls to equilibrate to room temperature(15-30°C) prior to
testing.2. Remove the test kit from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is
performed within one hour. 3. Place the test device on a clean and level surface.Transfer the specimen by a disposable specimen
dropper(or a pipette):To use a hold the dropper vertically,draw the specimen up to the fill line as shown in illustration
below(approximately 40uL).Transfer the specimen to the specimen well(S) of the test device and start the timer.Aviod trapping air
bubbles in the specimen well (S).4. Wait for the red line(s) to appear.The result should be read at 15 minutes. Do not interpret
the results after 20 minutes. Results:Positive:
In addition to a pink colored control (C) band,a Distinct pink colored band will also appear in the test (T) region.
*Note (Weak Positive):Colored band appearing in control Region (C) together with a faint colored band in Test Region (T).Negative:
Only one colored band appears on the control (C) region.No apparent band on the test (T) region.
Invalid:A total absence of color in both regions is
an indication of procedure error and/or the test reagent has deteriorated.


Format 
Speciman
Size (mm)
Strip
Whole Blood/Serum
2.5;3.0
Cassette
Whole Blood/Serum
2.5;3.0
Strip
Serum/Plasma
2.5;3.0
Cassette
Serum/Plasma
2.5;3.0
Detailed Images
Related Products
Packing & Delivery
Storage&Package
Our Service

1.Our services
GEMC is the short name of Gem Medic Electric & Technology Co.,Ltd located in Henan Province, China, which is a privately-held corporation high-tech enterprise specializing in trade of rapid medic diagnostic test kits and device. The main products we supply are pregnancy test kits, ovulation test kits, sperm fertility test, drug of abuse test, infectious disease test, saliva alcohol tester, digital clinical thermometer, blood pressure monitor,ovulation microscope monitor and other medical test device.
Since the foundation of company, based on the belief-product quality and service are the lifeline of enterprise, so now we have had global customers from all of over the world, such as France, Russia, UAE, Brazil, Mexico, Peru and south Africa, totally more than 70 countries and areas.
And we will sincerly hope supply more & better service for you, 'for your better health & happy life' is our working target, welcome to visit our website to know more about it, thanks.

2. How to order our product
(1) Customers to contact to consult , and purchase our products
(2) Our trader make a perfessional form according to your product
(3) Inform the product you need after you confirmation of the product

FAQ

Q1: What's the method u use to do the test?
A: Colloidal Gold Method.

Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.

Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.

Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.

Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.

Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:Technical data: Such as the accuracy, specificity and sensitivity.

Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.

Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.

Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice

Contact Us

Telephone: 86-371-60997506
Fax: 86-371-60997506
Website: http://www.gv-medic.com
Address: NO.20,Bosong Road, Zhengzhou, Henan ,China
Zip: 450001
City: Zhengzhou
Country: China (Mainland)

Electric Golf Cart
Inquiry