Product Description

 pHB-4.jpgpHB-4-1.jpg

1. Technical data

1,Acceptance

Please check the following device in the instrument box:

 portable pH meter 1 computers

The composite electrode 1

 short-circuit plug (has been inserted in the instrument back electrode socket) 1

 7 DC1.5V batteries (by express delivery is allowed) 4

 standard buffer reagent: 1 sets of pH4, pH6.86, pH9.18

 use manual 1

 product warranty card 1

 product certificate in 1 copies

 

2,Technical characteristics and application conditions of instrument

Model

PHB-1

PHB-4

Measuring range

pH:0~14.00pH

mV:±1600mV,

Temperature:0~60

pH:0~14.00pH

mV:±1999mV,

Temperature:0~60

Resolution

pH:0.01pH,

Temperature1

pH:0.01pH,

Temperature1

Precision

pH:0.01pH,Temperature1

pH:0.01pH,Temperature1

Temperature compensation

0-60Manual compensation

0-60Manual / automatic compensation

The basic configuration

E201-C plastic PH composite electrode

The PH standard calibration sample

7 DC1.5V 4 batteries

E201-C-W plastic PH temperature electrode

The PH standard calibration sample

7 DC1.5V 4 batteries

 

Working conditions

 environment temperature: 0 ~ 40  relative humidity: < 85%

for electric power: 1.5V battery /4 Festival

No significant vibration

 except without external magnetic field of the earth magnetic field interference

The input impedance: ≥ × 1012 Ω

 drift: ≤ 0.01pH ± 1 words / 2 hours

 solution temperature compensation range: 0 ~ 60 

The size and weight: 180 * 80 * 30MM (length * width * height) 0.5Kg

 power consumption: 2 W

3,The instrument work principle

The basic principle of pH measurement

Measurement of pH value in the water solution with glass electrode as indicator electrode, calomel electrode as reference electrode, when the hydrogen ion concentration in solution (strictly speaking is activity) that the pH value of the solution changes, electromotive force generated between the glass electrode and a calomel electrode with change, and the potential relationship with the following formula:

 E pH = 58.16 * * (273+t ) /293 (mV)

 E: indicates the potential change, the MV unit. (mV)

 pH: the pH values of solution.

T: that of tested solution temperature (C).

Indicator electrode used a glass electrode, the electrode, fluoride electrode, silver electrode, the glass electrode is the most widely used. PH glass electrode head is made of sensitive film special, it is sensitive to hydrogen ions, when it is inserted into the test solution, the potential change with hydrogen ion concentration and temperature of the solution. In the solution temperature is 25 1 per pH, the electrode potential changes 59.16mV. The theory of slope coefficient which is often said that the electrode.

The commonly used reference electrode for calomel electrode, the potential does not vary with the concentration of hydrogen ions in the solution was changed.

The measurement of pH value is the essence of the measured potential difference between two electrodes. When the potential of a pair of electrodes in the solution of the resulting difference is equal to zero, the measured pH value of the solution is zero potential value pH, it with the glass electrode in the solution of the relevant. The instrument used is composite electrode is composed of a glass electrode and Ag-Agcl electrode consisting of zero position, the pH value of 7 ± 0.25pH.

4,Method of use instrument

Preparation

 open the instrument back battery cover, install 1.5V 4 batteries (note the positive and negative class). Take short plug of instrument electrode socket, plug electrode. Note that the electrode plug should be kept clean and dry before use, should not be pollution.

· power press to open the key, preheat for 5 minutes.

Instrument calibration

Note: this instrument must use 4, 6.86, 9.18, three kinds of standard buffer solution calibration.

In the pH before the measurement, we need to instrument calibration. To obtain accurate measurement results, calibration with standard buffer solution should be accurate and reliable.

Switch on the power, press the "switch" boot.

Unscrew the short-circuit protection pH socket on the cover, access plastic pH composite electrode, the electrode in pure water and clean and dry.

By measuring the pH thermometer buffer solution temperature, pressing the button "" or reduce the key "" will display the temperature value accurate adjustment.

The location and calibration: pH electrodes immersed in pH6.86 buffer, stir it still be placed, measured value stability, hold down the "calibration" key and do not put, let go when the LCD screen display CAL symbol, to show flashes of 6.86, after a few seconds display End symbols, and then show the pH calibration (this pH is displayed value varies with temperature, such as 25  showed 6.86, 15  showed 7.04 of these are numerical, built-in chip set below). Said to complete the calibration and memory.

The slope of calibration of I: remove the PH electrode, pure water and clean and dry, then PH electrodes immersed in pH4.00 buffer, stir it still be placed, measured value stability, hold down the "calibration" key and do not put, let go when the LCD screen displays the CAL symbol, the first display flashing 4, a few seconds after the show End symbol, and then display the pH calibration values, indicating the completion of calibration and memory. After the calibration will automatically display electrode in the linear section of the slope percentage.

The slope of calibration of II: remove the pH electrode, pure water and clean and dry, then PH electrodes immersed in pH9.18 buffer, stir it still be placed, measured value stability, hold down the "calibration" key and do not put, let go when the LCD screen displays the CAL symbol, the first display flashing 9.18, a few seconds after the show End symbol, and then display the pH calibration values, indicating the completion of calibration and memory.

Packaging & Shipping

 QQ20200717155757.pngQQ20200717160345.png

Our Services

1. Our service

 

Gemc are synonymous with quality, personalized service and a commitment to excellence.  With our specialized rapid, diagnostic test technologies, high quality assurance, brand recognition, innovative research and development techniques, customer-centric design, an experienced management team, and an energetic sales force, Gemc continues to set the standards in product quality and reliability.  We believe in continually improving our products and service, and making the business relationship a beneficial experience for both customers and employees.  

 

 

 Based on our core competence in rapid test technology, high quality assurance in products, international renowned brand name, innovative R&D, customer-centric product design as well as strong sales network, the experienced management team and energetic sales force of Gemc will lead our life to achieve peacefulness, harmony, and higher quality.

 

 

2. How to order our product

 

(1) Customers to contact to consult , and purchase our products

(2) Our trader make a perfessional form according to your product

(3) Inform the product you need after you confirmation of the product

 

Certifications

CE Certificates

 

Contact us

Telephone: 86-371-60997506  
Mobile Phone: 008615303821307
           Fax: 86-371-60997506

     Website: http://www.gv-medic.com
    Address: NO.20,Bosong Road, Zhengzhou, Henan ,China

              Zip: 450001
            City: Zhengzhou

    Country: China (Mainland)

Electric Golf Cart
Inquiry