Fostream Reverse Osmosis Salt Water Purifiers/RO Salt Water Filter Machine
Raw water source: Sea water, Salt water, Brackish water
1. First class Danmark Danfoss(or others)high-pressure pump of corrosion-resistant, ultra reliable, high-performance.
2. Small size, low weight, easy to operating, installation and maintenance.
3. Made in U.S (DOW) supreme quality Reverse Osmosis membranes for excellent desalination rate, durability and efficiency.
4. High-density 5-micron sediment filters to remove impurities from feed water during the pre-filtering process so as to extend the service life of Reverse Osmosis membranes.
5. Accurate real-time monitoring of the systems working pressures by top-graded meters specifically designed for maritime use. Real-time TDS water quality monitoring with digital display.
6. Water levels and over-pressure warning alarms with light and sound warning signals together with automatic shutdown protection to ensure the system is operating safely and properly.
7. System equipped with Food Safety Level UPVC pipelines and premium quality 316 stainless steel valves and interfaces.
8. With heavy duty corrosion-resistant steel and anti-corrosion coated framework, the system is able to operate durably and stably under harsh environments with high temperature, high humidity and high salinity conditions..
Working process
Raw seawater tank→Booster pump→Sand filter→Activated carbon filter→5μm micro filter→1μm micro filter→High pressure pump→Seawater Reverse osmosis system (with Automatic RO backwash)→Output pure living water
Technical Data
Model | Capacity of water (Ton/hour) | General Power (KW) | Electrical Power (50-60Hz) | Membrane (Pic) | Size (L*W*H) ( mm) | Weight (Kg) |
RO-100L/H | 0.1 | 0.2 | AC220V | EC4021-800A | 690*570*1490 | 100 |
RO-300L/H | 0.3 | 2.75 | AC220V 18A / 380V 9A | ESPA4040*2 | 1550*900*1820 | 150 |
RO-500L/H | 0.5 | 2.75 | AC220V 18A / 380V 9A | ESPA4040*3 | 1550*900*1820 | 250 |
RO-700L/H | 0.7 | 4.25 | AC220V 27.5A / 380V 13A | ESPA4040*4 | 1550*900*1820 | 350 |
RO-1000L/H | 1 | 3.75 | AC220V 24A / 380V 12A | ESPA4040*4 | 1980*900*1940 | 500 |
RO-2000L/H | 2 | 4.75 | AC380V 8.8A | ESPA4040*6 | 4800*700*2050 | 700 |
RO-3000L/H | 3 | 5.75 | AC380V 10A | ESPA4040*7 | 6000*800*2200 | 800 |
RO-4000L/H | 4 | 7.5 | AC380V 12A | ESPA4040*8 | 7000*900*2400 | 1000 |
RO-5000L/H | 5 | 12.5 | AC380V 25A | ESPA8040*9 | 8000*1000*2700 | 1500 |
Our products are sold well not only in domestic, but also in Chile,Venezuela,Egypt,Peru,Maldives,United States,Brunei Darussalam,Saudi Arabia,Panama,Cambodia,Bhutan,Bolivia,Bulgaria,Nicaragua,Dominican Republic,Kenya,Somalia,Australia,Switzerland,Mozambique and other countries.
If you want to know more about our transaction history. Pls click | VIEW MORE > |
1.Are you a factory or trading company?
Yes, we are a manufacture with designing, manufacturing, marketing and exporting.
2.Where is your factory located? How can I visit there?
Our factory is located in No. 2, Liantang Road, Chaolian Town, Pengjiang District, Jiangmen, Guangdong, China, All our clients, from home or abroad, are warmly welcome to visit us!
3.What products does your company offer by yourself?
We are specialized in RO water treatment machines,UF water treatment machines,Sea water desalination machines,small bottle filling machines and 5 gallon filling machines etc.
4.How do you usually pack the exported goods?
We usually use bubble bag, then wooden box with pallet.
5.Which machine should I choose?
It depends on your raw water quality and your requirements for permeate water.
6.What’s your warranty?
Our warranty is 1 year. But normally, our machine can work 5 years before repair.
7. Maintenance :
1, check all circuit whether damaged.
2, check valve whether malfunctioning phenomenon.
3, check all pipes for leaks.
4, If long time no use , need to add protective solution to protect the reverse osmosis .
(1) Open inlet which in the front of the high-pressure pump (see illustration), make well the protective solution in the water tank ,then connect with the tank via pipe , start the water tank pump, when the protective solution full filled with reverse osmosis membrane group, turn off the water tank pump, close the inlet. Meanwhile every day to observe, such as protection fluid leakage situation, should replenish the above step.
(2) Before equipment startup , protective solution should be clear up .
8. Troubleshooting:
1.high-pressure pump:
Each work 200 hours to inspect, pressure whether normal, whether the crankcase short of oil, the pump whether abnormal and other tests, such as abnormal working, in accordance with the manufacturers instructions for maintenance. If do not have maintenance skills, please timely contact with the manufacturer, we will maintenance for client.
2.booster pump:
Maintenance, inspection, refer to the high-pressure pump, the specific details, see the lift pump manual requirements. Equipment failure, if you are able to maintenance and repair, the manufacturer can provide technical support. If do not have skills to repair, made it clear that the cause of the malfunction and fault coverage, please contact the manufacturer.
COME TO HOME PAGE >> |
Related Products | ||
5 Gallon Barrel Water Filling Production Solution |