Product description

Flexible:Available in up to 12 parameters

Urine Reagent Strips (URS) for Urinalysis are firm plastic strips to which several different reagent areas are affixed. Depending on the product being used, Urine Reagent Strips provide tests for Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes, and Ascorbic Acid in Urine. Test results may provide information regarding the status of carbohydrate metabolism, kidney and liver function, acid-base balance, and bacteriurea.1,2 Please refer to the outside box and bottle label for the specific test parameters of the product you are using

A urine test strip is a basic diagnostic instrument used to determine pathological changes in the urine in standard urinalysis. A standard urine test strip may comprise of up to 12 different chemical pads or reagents which react (change color) when immersed in, and then removed from, a urine sample. The test can be read between 60 and 120 seconds after dipping. Routine testing of the urine with multiparameter strips is the first step in the diagnosis of a wide range of diseases

Visual Reading Technique:

  • Hold the strip up horizontally and compare the result shown on the strip with the color chart on the canister label closely and carefully. Take note of the result. For a semi-quantitative result, take down the results according to the time specified on the color chart. The pH and Protein can be read at any time within 60 seconds after dipping. For a qualitative result, the strip should be read 1-2 minute after dipping. If a positive result is obtained, repeat the test and compare with color chart at the time specified. Color changes beyond 2 minutes are of no diagnostic value.

Our factory produces with a competitive price. The relevant quotation and samples will be sent upon request

Dip the test strip for about 1 second into the fresh urine specimen

496386415_723.jpg

Wipe off any excess urine on the rim of the vessel and blot the edge of the test strip on tissue paper

.jpg

 Testing Items:  Leucocyte Nitrite Urobilinogen Protein pH Blood Specific Gravity Ketone Bilirubin Glucose

  • Glucose
    This test is based on a sequential enzyme reaction. First, glucose oxidase catalyzes the formation of gluconic acid and hydrogen peroxide from the oxidation of glucose. A second enzyme, peroxidase, catalyzes the reaction of hydrogen peroxide with potassium iodide chromogen to oxidize the chromogen to colors ranging from blue through greenish-brown, and brown to dark-brown.
    Reactivity of the test decreases as the specific gravity and/or pH of urine increases, and may also vary with temperature. Ascorbic acid (more than 50 mg/dl) and ketone bodies (more than 40 mg/dl) may cause a false negative result for a specimen containing a small amount of glucose (100 mg/dl). However, the combinations of such ketone levels and low glucose levels are metabolically improbable..

Read the result by comparing the test fields with the color scale on the test pack after 30 to 60 seconds

.jpg 

VISUAL READING TECHNIQUE:

  1. Immerse all reagent areas in specimen and remove strip immediately.
  2. Run edge of strip against the rim of the container to remove excess urine.
  3. Compare test areas closely with colour chart on bottle label or bench reader. Record the results.

VISUAL READING TECHNIQUE.jpg

Instruction:

  • Dip the test patch of a fresh strip into urine sample, or pass strip through urine stream 1 to 2 seconds only.
  • Blot excess on a clean paper towel or tissue.
  • Results may be compared between 1 minute od exposure to urine(colour changes occuring after 1 minute are of no diagnostic value)

product mix.jpg

Notes:

  1. Do not touch test areas of reagent strips.
  2. Do not use after expiry date
  3. Do not remove desiccant(s).
  4. Do not remove strip from the bottle until immediately before it is to be used for testing.
  5. Replace cap immediately and tightly after removing reagent strip.
  6. Store at temperature between 2°C-30°C.
  7. Store only in original bottle.
  8. The sample should not be more than 4 hours old at the time of testing.
  9. Collect fresh urine in a clean dry container.