Eurovent Supreme Energy Efficiency  A++  SCOP4.0 lower noise 24000btu wall split air conditioner 

 

 

 
Product Description

  

Wall Split Air Conditioner Specification Sheet

 

 

       
Model OS-24HRFN1
Power supply Ph-V-Hz 220-240V~ 50Hz, 1Ph
Rated Cooling Capacity                      Btu/h 22000(7240~24640)
Cooling Power input   W 171~2780
Cooling  Current   A 0.74~12.09
Rated Heating Capacity         Btu/h 25000(4600~30000)
Heating Power input   W 235~3140
Heating Current   A 1.02~13.65
Seasonal Cooling Pdesignc kW 6.4
SEER W/W 6.1
Energy Efficiency Class   A++
Heating(Average ) Pdesignh kW 5.2
SCOP W/W 4.0
Energy Efficiency Class   A+
Tbiv -7
Heating(Warmer ) Pdesignh kW 7.1
SCOP W/W 4.8
Energy Efficiency Class   A++
Tbiv 5
Tol -15
Moisture Removal             L/h 2.3
Max. input consumption         W 3100
Max. current                A 14.5
Starting current                A ----
Compressor Model    DA150S1C-20FZ
Type    Twin-rotary
Brand    TOSHIBA 
Capacity      Btu/h 15286
Input           W 1150
Rated current(RLA)  A 9.7
Locked rotor Amp(LRA)    A ----
Thermal protector    KSD301
Thermal protector position   EXTERNAL
Capacitor       uF ---
Refrigerant oil/oil charge   ml ESTER OIL VG74/500
Indoor fan motor Model    WZDK58-38G
Brand    Shibaura
Output       W 58
Capacitor        uF - -
Speed(Hi/Mi/Lo) r/min 1180 / 1100 / 900
Indoor coil a.Number of rows   2
b.Tube pitch(a)x row pitch(b)   mm 21x13.37
c.Fin spacing                 mm 1.3
d.Fin type (code)   Hydrophilic aluminium
e.Tube outside dia.and type  mm Φ7, innergroove tube
f.Coil length x height x width   mm 780x336x26.74
g.Number of circuits   4
Indoor air flow (Hi/Mi/Lo) m3/h 1150/1070/880
Indoor sound pressure level  (Hi/Mi/Lo) dB(A) 49/43/36
Indoor sound power level (Hi) dB(A) 62
Indoor unit Dimension(W*D*H) mm 1045x235x315
Packing   (W*D*H) mm 1135x395x315
Net/Gross weight   Kg 12/15.2
Outdoor fan motor Model    WZDK50-38G
Brand    Shibaura
Output       W 50
Capacitor        uF - -
Speed         r/min 800
Outdoor coil a.Number of rows   2
b.Tube pitch(a)x row pitch(b)   mm 25.4x22
c.Fin spacing                 mm 1.4
d.Fin type (code)   Hydrophilic aluminium
e.Tube outside dia.and type  mm Φ9.52,innergroove tube
f.Coil length x height x width   mm 766x660x44
g.Number of circuits   4
Outdoor air flow             m3/h 2700
Outdoor sound pressure level dB(A) 60
Outdoor sound power level         dB(A) 67
Outdoor unit Dimension(W*D*H) mm 845x320x700
Packing  (W*D*H) mm 965x395x755
Net/Gross weight   Kg 47 / 50
Refrigerant           Type    R410A
GWP   1975
Charged quantity Kg 1.95
Design pressure              MPa 4.2/1.5
Refrigerant piping Liquid side/ Gas side   mm(inch) Φ9.52/Φ15.9(3/8"/5/8")
Max. refrigerant pipe length    m 30
Max. difference in level        m 20
Connection wiring       2.5(Optional)
Plug type   --
Thermostat type   Remote Control
Operation temperature Indoor(cooling/ heating) 17~32/0~30  
Outdoor(cooling/heating) -15~50/-15~30
Application area             m2 32-53
Qty’per 20’ /40’ /40'HQ      69/140/160

 

 

 

 

Features: 

 

 

 

Mute Operation

On the basis of low noise air duct system and quiet design, you can shut off the AC beep and display by pressing mute operation to create a super-quiet environment.

585.jpg

 

Selectable Control Modes

Apart from the conventional remote control, Aurora split to provide a variety of optional, including wired control, front desk control, and central control.

8999.jpg

Optional functions:   (If you need below add functions, please let me know) 

 

 1. Active carbon Filter

 

2. Photocatalyst Filter

 

3. Catechin Filter

 

4. Vitamin-enriching Filter

 

5.  Nano Silver Filter

 

6. Air Ionizer

 
Our Services

 

 

1. Olyair Appliances insist high-quality products reach every client are safe without worry, so we will fully test each pc of the product before leaving the factory. 

 

2. As HVAC products we provide a three-year warranty for the whole unit and the compressor all use famous brands like Toshiba etc. 

and it lasts five years warranty also. 

 

3. Each full container we will free to combine with 0.5%-1% spare parts based on each product's request. 

 

4. Olyair Provide OEM service which will is responsible for design the indoor and outdoor carton box. If you need have our own panel design request just contact us we will ask an engineer to give a strong idea for your long term development. 

 

5. In general, when we receive your inquiry message, our information dept will send related colleague for the first time. So you will receive a reply within one hour. And if no response, please contact our service team or visit our web to get some contact information. 

 

6. We thank you for each client to read any products on the web, so please let both of us value time before sending inquiries. please consider the products and it's a specification you really need.  Sometimes,  some inquiry no any subject and don't confirm what they want, but just request to inform the payment terms and MOQ which made us difficult in reply to an inquiry.

 

 
Packaging & Shipping

  

  

Wall Split Packing

 

Olyair .JPG

 

Window Packing Carton:

 

olyair window packing box.jpg

Floor Standing Packing:

 

olyair .jpg

 55.jpg

 

 

11063560.JPG

 

Company Information

 

 

36020140810232355985.jpg

01.jpg02.jpg05.jpg08.jpg

 

 

 
FAQ

  

1. Why the heating of the air conditioner does not function?
 
Answer: Our remote control is designed to have both ‘cooling only’ mold and ‘cooling & heating’ mold. Users need to activate either the ‘cooling only’ mold or the ‘cooling & heating’ mold. If ‘cooling only’ mode is activated, the heating function of the air conditioner will not work, it will starting heating up the room temperature only when you turn it into a ‘cooling & heating’ mold. The way of setting is demonstrated in detail in the user’s manual.
 
2. Why the air conditioner does not blow out hot air until several minutes after it is activated?
 
Answer: This is because when the heating mold just started, the temperature of the evaporator is relatively low and the wind blow out would be cool. Therefore, there has designed a function of cool air protection, which will stop the indoor fan from working until the evaporator reaches the set temperature. Thus, there will not be any wind blow out at the beginning.
 
 
3. Why the air conditioner does not work for the first 3 minutes after it is restarted after a sudden power loss?

 


Answer: This is because our air conditioning has been set up with the power lost memory function (AUTO - RESTART), when suddenly power off and then immediately power on, the air conditioner will operate according to the same setting before the power off. Therefore, in order to prevent the impact of the imbalance system to the compressor on its startup, the compressor will re-start operating 3 minutes delay. Thus, the condition will not either heat up or cool down the room temperature in these 3 minutes.
 
4. Why the capacity of the new air condition seemed not strong enough to cool down the room temperature?

 

 


Answer: There could be various reasons:
1) The capacity is insufficient, professional will be necessary for checking.
2) Wrong model of an air conditioner is brought, as the choice of models has a direct relationship with the following conditions:
A. The area of the room.
B. The cooling load of the room. It is related to the heat leakage, which is affected by the thermal insulation of the room wall, large glass window, and no. of heating source such as high voltage home appliances. The heat leakage will also be affected in places such as the dining room and living room.
To our experience, the capacity of air conditioner = room area X cooling load, the cooling load can be between 160 to 220, depending on the heat leakage. For example, if there are not any large voltage home appliances and the thermal insulation is ok, the cooling load of a single room can be estimated as 160, and 170 for a double room, 200 for a living room, and 220 for a dining room. Commercial areas should be estimated according to real situations.

 

 

Our client from Euro union Countries should know the below request before order air conditioner into your country.

 

In the lastest 2013, July, Euro union countries have below: 

 

 

112.jpg

 

1.Austria
2.Belgium
3.Bulgaria
4.Cyprus
5.Croatia
6.CzechRepublic
7.Denmark
8.Estonia
9.Finland
10.France
11.Germany
12.Greece
13.Hungary
14.Ireland
15.Italy
16.Latvia
17.Lithuania
18.Luxembourg
19.Malta
20.Netherlands
21.Poland
22.Portugal
23.Romania
24.Slovakia
25.Slovenia
26.Spain
27.Sweden
28.United Kingdom

 

 

 1.  As the EU requirement on the air conditioner and single duct and double duct portable air conditioner is ERP standard. 

And the energy efficiency will higher and higher which moves step by step. Some clients if not in the HVAC region may not be very clear the policy. Below chart in each degree to show you how different on the new ERP Stanard compare old EER rating. 

 

 

Energy label Difference: 

 

36020140811114554666.jpg

 

 

 

Olyair models from residential to commercial are reaching New class A ranking, the highest level that is now shown on energy label in Europe union.

 

New Energy Labelling Requirement (EU) 626/2011

• Three climate zones for heating
(Average zone is mandatory, warmer and
the colder zone is voluntary)

 

• Seasonal efficiency
(performance based on multiple part loads