Products
Search
Categories
Electronics Product Beauty / Personal Care Furniture / Building Materials Automotive Machinery Clothing Accessories Home Department Store International Logistic Service
Contact Supplier
To: Annie Fu
Product description

 

Olyair dc inverter air conditioner 

 

 
Product Description

  

Specification Sheet

 

 

    
ModelOS-24HRFN1
Power supplyPh-V-Hz220-240V~ 50Hz, 1Ph
Rated CoolingCapacity                     Btu/h22000(7240~24640)
Cooling Power input W171~2780
Cooling  Current A0.74~12.09
Rated HeatingCapacity        Btu/h25000(4600~30000)
Heating Power input W235~3140
Heating Current A1.02~13.65
Seasonal CoolingPdesignckW6.4
SEERW/W6.1
Energy Efficiency Class A++
Heating(Average )PdesignhkW5.2
SCOPW/W4.0
Energy Efficiency Class A+
Tbiv-7
Heating(Warmer )PdesignhkW7.1
SCOPW/W4.8
Energy Efficiency Class A++
Tbiv5
Tol-15
Moisture Removal            L/h2.3
Max. input consumption        W3100
Max. current               A14.5
Starting current               A----
CompressorModel  DA150S1C-20FZ
Type  Twin-rotary
Brand  TOSHIBA 
Capacity     Btu/h15286
Input          W1150
Rated current(RLA) A9.7
Locked rotor Amp(LRA)   A----
Thermal protector  KSD301
Thermal protector position EXTERNAL
Capacitor      uF---
Refrigerant oil/oil charge  mlESTER OIL VG74/500
Indoor fan motorModel  WZDK58-38G
Brand  Shibaura
Output      W58
Capacitor       uF- -
Speed(Hi/Mi/Lo)r/min1180 / 1100 / 900
Indoor coila.Number of rows 2
b.Tube pitch(a)x row pitch(b)  mm21x13.37
c.Fin spacing                mm1.3
d.Fin type (code) Hydrophilic aluminium
e.Tube outside dia.and type mmΦ7, innergroove tube
f.Coil length x height x width  mm780x336x26.74
g.Number of circuits 4
Indoor air flow (Hi/Mi/Lo)m3/h1150/1070/880
Indoor sound pressure level  (Hi/Mi/Lo)dB(A)49/43/36
Indoor sound power level (Hi)dB(A)62
Indoor unitDimension(W*D*H)mm1045x235x315
Packing   (W*D*H)mm1135x395x315
Net/Gross weight  Kg12/15.2
Outdoor fan motorModel  WZDK50-38G
Brand  Shibaura
Output      W50
Capacitor       uF- -
Speed        r/min800
Outdoor coila.Number of rows 2
b.Tube pitch(a)x row pitch(b)  mm25.4x22
c.Fin spacing                mm1.4
d.Fin type (code) Hydrophilic aluminium
e.Tube outside dia.and type mmΦ9.52,innergroove tube
f.Coil length x height x width  mm766x660x44
g.Number of circuits 4
Outdoor air flow            m3/h2700
Outdoor sound pressure leveldB(A)60
Outdoor sound power level        dB(A)67
Outdoor unitDimension(W*D*H)mm845x320x700
Packing  (W*D*H)mm965x395x755
Net/Gross weight  Kg47 / 50
Refrigerant          Type  R410A
GWP 1975
Charged quantityKg1.95
Design pressure             MPa4.2/1.5
Refrigerant pipingLiquid side/ Gas side  mm(inch)Φ9.52/Φ15.9(3/8"/5/8")
Max. refrigerant pipe length   m30
Max. difference in level       m20
Connection wiring     2.5(Optional)
Plug type --
Thermostat type Remote Control
Operation temperatureIndoor(cooling/ heating)17~32/0~30  
Outdoor(cooling/heating)-15~50/-15~30
Application area            m232-53
Qty’per 20’ /40’ /40'HQ     69/140/160

 

 

Mute Operation

On the basis of low noise air duct system and quiet design, you can shut off the AC beep and display by pressing mute operation to create a super quiet environment.

585.jpg

 

Selectable Control Modes

Apart from conventional remote control, Aurora split provide a variety of optional, including wired control, front desk control and central control.

8999.jpg

Optional functions:   (If you need below add functions, please let me know) 

 

 1. Active carbon Filter

 

2. Photocatalyst Filter

 

3. Catechin Filter

 

4. Vitamin-enriching Filter

 

5.  Nano Silver Filter

 

6. Air Ionizer

 
Our Services

 

 

1. Olyair Appliances insist high quality products reach every clients are safe without worry, so we will fully test each pc of product before leave factory. 

 

2. As HVAC products we provide three year warranty for whole unit and compressor all use famous brand like toshiba, rechi etc. 

and it lasts five years warranty also. 

 

3. Each full container we will free to combine with 0.5%-1% spare parts based on each products request. 

 

4. Olyair Provide OEM service which will in responsible for design the indoor and outdoor carton box. If you need have own panel design reqiuest just contact us we will ask engineer to give a strong idea for your long term development. 

 

5. In general, when we receive your inquiry message, our information dept will send related colleage in the first time. So you will receive a reply within one hour. And if no any response, please contact our service team or visit our web to get some contact information. 

 

6. We thank you for each client to read our any products in the web, so please let both of us value time, before send inquiry. please consider the products and it's specification you really need.  Sometimes,  some inquiry no any subject and don't confirm what they want, but just request to inform the payment terms and MOQ which made us difficult in reply an inquiry.

 

 
Packaging & Shipping

  

  

Wall Split Packing

 

Olyair .JPG

 

Window Packing Carton:

 

olyair window packing box.jpg

Floor Standing Packing:

 

olyair .jpg

 55.jpg

 

566.jpg

 

Company Information

 

 

36020140810232355985.jpg

01.jpg02.jpg05.jpg08.jpg

 

 

 
FAQ

  

1. Why the heating of the air conditioner does not function?
 
Answer: Our remote control is designed to have both ‘cooling only’ mold and ‘cooling & heating’ mold. Users need to activate either the ‘cooling only’ mold or the ‘cooling & heating’ mold. If ‘cooling only’ mode is activated, the heating function of the air conditioner will not work, it will starting heating up the room temperature only when you turn it into ‘cooling & heating’ mold. The way of setting is demonstrated in detail in the user’s manual.
 
2. Why the air conditioner does not blow out hot air until several minutes after it is activated?
 
Answer: This is because when the heating mold just started, the temperature of evaporator is relatively low and the wind blow out would be cool. Therefore, there has designed a function of cool air protection, which will stop the indoor fan from working until the evaporator reach the set temperature. Thus, there will not be any wind blow out at the beginning.
 
 
3. Why the air conditioner does not work for the first 3 minutes, after it is restarted after a sudden power lost?

 


Answer: This is because our air conditioning has been set up with the power lost memory function (AUTO - RESTART), when suddenly power off and then immediately power on, the air conditioner will operate according to the same setting before the power off. Therefore, in order to prevent the impact of imbalance system to the compressor on its startup, the compressor will re-start operating 3 minutes delay. Thus, the condition will not either heat up or cool down the room temperature in these 3 minutes.
 
4. Why the capacity of new air condition seemed not strong enough to cool down the room temperature?

 

 


Answer: There could be various reasons:
1) The capacity is insufficient, professional will be necessary for checking.
2) Wrong mode of air conditioner is brought, as the choice of models has a direct relationship with the following conditions:
A. The area of the room.
B. The cooling load of the room. It is related to the heat leakage, which is affected by the thermal insulation of room wall, large glass window and no. of heating source such as high voltage home appliances. The heat leakage will also be affected in places such as dining room and living room.
To our experience, capacity of air conditioner = room area X cooling load, cooling load can be between 160 to 220, depend on the heat leakage. For example, if there are not any large voltage home appliances and the thermal insulation is ok, the cooling load of a single room can be estimated as 160, and 170 for a double room, 200 for a living room and 220 for a dining room. Commercial areas should be estimated according to real situations.

 

 

 Our client from Euro union Countries should know below request before order air conditioner into your country.

 

In the lastest 2013, July, Euro union countries has below: 

 

 

112.jpg

 

1.Austria
2.Belgium
3.Bulgaria
4.Cyprus
5.Croatia
6.CzechRepublic
7.Denmark
8.Estonia
9.Finland
10.France
11.Germany
12.Greece
13.Hungary
14.Ireland
15.Italy
16.Latvia
17.Lithuania
18.Luxembourg
19.Malta
20.Netherlands
21.Poland
22.Portugal
23.Romania
24.Slovakia
25.Slovenia
26.Spain
27.Sweden
28.United Kingdom

 

 

 1.  As EU requirement on air conditioner and single duct and double duct portable air conditioner is ERP standard. 

And the energy efficiency will higher and higher which move step by step. Some client if not in HVAC region may not be very clear 

the policy. Below chart in each degree to show you how different on the new ERP stanard. 

 

 

Energy label Difference: 

 

36020140811114554666.jpg

 

 

 

Olyair models from residential to commercial are reaching New class A ranking, the highest level that is now shown on energy label in Europe union.

 

New Energy Labelling Requirement (EU) 626/2011

• Three climate zones for heating
(Average zone is mandatory, warmer and
colder zone are voluntary)

 

• Seasonal efficiency
(performance based on multiple part loads
calculation)

 

Sound power level
• Rated efficiency indicates performance only at a rated condition.
Seasonal efficiency indicates performance at an entire cooling and heating season, which better matches the actual operation.
High Efficiency

 

0023.jpg

 

 

 

 

 

 

Electric Golf Cart
Inquiry