Gentle hint:
Communication first, then place the order
There are more surprises awaiting you!!!!
12v 150 ah rechargeable Front access terminal AGM lead acid battery
Application
1. All purpose
2.Uninterruptable Power Supply (UPS)
3.Electric Power System (EPS)
4.Emergency light
5.Emergency backup power supply
6.Auto control system
7.Aircraft signal
8.Alarm and security system
9.Electronic apparatus and equipment
10.DC power supply
11.Communication power supply
“ESG”battery are sold well all over the world,especially in Europe,America,Australia,India,Bangladesh etc. We believe that our modern techniques and reasonable price will be the key to open your local market so that we can achieve win-win. As the core brand in Aoxin, “ESG” embeds “Quality, Loyalty, Service and Development” and enjoys an excellent reputation i -n both domestic and global markets. “ESG” is dedicated to providing the best batteries and services to customers from all parts of the world.
The extremely powerful and reliable Ever Exceed’s Deep Cycle batteries perfectly fulfills the requirement for many different applications including telecommunications for many different applications including telecommunications, home medical equipment (HME)/ mobility, industrial and utility applications where frequent deep cycle are required and minimum maintenance is desirable. Our development team combines the market’s demand with design optimization, precision component selection and state-of-the-art manufacturing process to produce the most cost-effective battery solution for today’s applications.
Applicable operating temperature range:-10°C~+50°C
Ideal operating temperature range: +20°C~ +30°C
Storage time from a fully charged condition: 24 months at 25°C, for each 10°C rise, reduce the storage time by half.
ESG VRLA battery Front Access battery 12v 150ah FT Telecommunication Battery
Technology
Other Battery Model
Battery DOD
Different Battery Terminal
Our Battery VS Other Supplier Battery
Complete Chain
front in terminal AGM Battery 12v150ah
The QC for Deep-Cycle lead acid Batteries
China SLA Deep cycle VRLA Front access terminal AGM battery 12v 150 ah for telecom UPS
Precautions
• Always handle batteries with care.
• Always store upright.
• Never over-fill with acid.
• Always charge in a well ventilated place.
• Always wear eye protection when handling batteries.
• Wear protective clothing if there is any rick of acid splashing.
Danger
• Do not use at the places near fire. Hydrogen gas generated from battery may cause fire and explosion.
• This 12v battery is only for starting engine. Do not apply for other uses.
• Keep out of the reach of children or the personnel who do not understand the manual. It may cause blindness or severe burn.
• When using the battery, wear safety glasses and rubber gloves.Sulfuric acid may cause blindness or severe burn.
Warning
• Replacement of battery shall be performed as per following order. If failed, it may cause fire and explosion. Remove cable from negative terminal first.Connect cable to negative terminal last.
• When connect cable to battery, make sure not to get changed post of +and -. It may cause the damage of electronic components or fire.
• When ueing the battery ,handle with care,sulfuric acid may cause blindness or severe burn.
Caution
• When moving battery, be careful not to drop the battery , which is heavy, Do not shake the battery with handle, if there is the handle, It may cause the injury.
• Do not shore the battery at the following places. High temperature and humidity. Being exposed to rain,snow, direct sunshine.
ESG Registered Company in HK managed with foreign mentality.
Our China factory shall be the biggest sealed lead acid battery factory in Guangdong province, Foshan City.
Total site over 70000 square meter, construction land over 50000 square meter long.
Total investment value is over USD30 million.
Manufacture full range of three brand sealed lead acid rechargeable battery 2V, 4V, 6V, 8V, 12V and 14V series.
We control quality from the material production process of oxidation, plate production, to battery assembly (including in-house plastic case injection& moulding dept).
ESG has in-house advanced Swiss ARL Spectrometer, Chemical Lab, Germany Digatron full set battery-testing Laboratory Equipment& Digatron charge-discharge production system to ensure quality& support R&D.
ESG batteries are honourably recognized by SGS and SGS, and also have CE mark.
ISO 9001-2000 And OHSAS 18001 Certified.
Annual sales turn over is over USD100 million.
Annual production capacity is over 20 million pieces and 1 million KVA power.
Our testing reporter for lead acid Batteries
front in terminal AGM Battery 12v150ah
Certificate for lead acid Batteries
ESG VRLA battery Front Access battery 12v 150ah FT Telecommunication Battery
9. Our Services
1.Price cheapest --- complete production line
2.29years history---Before was Sino-Japanese joint venture government
3.Quality 100% pass testing
4.Payment term. LC .DA .DP .OA etc.
5.Free sample for you testing.
6.Fast service.
W China SLA Deep cycle VRLA Front access terminal AGM battery 12v 150 ah for telecom UPS
12v 150 ah rechargeable Front access terminal AGM lead acid battery
Battery Terms, Definitions, and Glossary for reference
· Acid
· A type of chemical that can release hydrogen ions when mixed with water. Sulfuric acid is used in a lead-acid battery.
· Active Material
· The porous structure of lead compounds that produces and stores electrical energy within a lead-acid battery. The active material in the positive plates is lead dioxide and that in the negative is metallic sponge lead. When an electrical circuit is created, these materials react with sulfuric acid during charging and discharging according to the following chemical reaction: PbO2 + Pb + 2H2SO4 = 2PbSO4 + 2H2O.
· AGM (Absorbent Glass Mat)
· A type of non-woven separator material composed almost entirely of glass microfibers that absorbs and retains the electrolyte, leaving no free electrolyte in the cell to spill. VRLA batteries made with this material are often referred to as "AGM" batteries.
· Ampere (Amp, A)
· The unit of measure of the electron flow rate, or current, through a circuit.
· Ampere-Hour (Amp-Hrs, Ah)
· A unit of measure for a battery’s electrical storage capacity, obtained by multiplying the current in amperes by the time in hours of discharge. (Example: A battery that delivers 5 amperes for 20 hours delivers 5 amperes x 20 hours = 100 amp-hrs of capacity.)
· Boost Charge
· The process of ensuring that the cells and plates within a battery are charged sufficiently for the battery to perform its desired function. Boost charging is typically done for a short duration at high current.
· BCI Group
· The Battery Council International (BCI) Group Number "fingerprints" a battery with the following characteristics: (a) dimensions (L x W x H), (b) voltage (6V or 12V), (c) polarity (right-hand front positive, left-hand front positive, etc.), (d) type terminals (top, side, "L", etc.). The BCI Group Number does not designate a battery’s capacity; it merely defines the above-listed physical characteristics.
· Capacity
· The capacity of a battery is specified as the number of amp-hrs that the battery will deliver at a specific discharge rate and temperature. The capacity of a battery is not a constant value and is seen to decrease with increasing discharge rate. The capacity of a battery is affected by a number of factors such as active material weight, density of the active material, adhesion of the active material to the grid, number, design and dimensions of plates, plate spacing, design of separators, specific gravity and quantity of available electrolyte, grid alloys, final limiting voltage, discharge rate, temperature, internal and external resistance, age and life history of the battery.
· Cell
· The basic electrochemical current-producing unit in a battery, consisting of a set of positive plates, negative plates, electrolyte, separators and casing. In a lead-acid battery, the cell has an open-circuit voltage of approximately 2 volts. There are six cells in a 12-volt lead-acid battery.
· Charge Acceptance
· The quantity of current in ampere-hours which a battery in a defined charge state can accept at a specified temperature and charge voltage within a defined period.
· Circuit
· An electrical circuit is the path followed by a flow of electrons. A closed circuit is a complete path. An open circuit has a broken, or disconnected, path.
· Circuit (Parallel)
· A circuit that provides more than one path for the flow of current. A parallel arrangement of batteries (usually of like voltages and capacities) has all positive terminals connected to a conductor and all negative terminals connected to another conductor. If two 12-volt batteries of 50 ampere-hour capacity each are connected in parallel, the circuit voltage is 12 volts, and the ampere-hour capacity of the combination is 100 ampere-hours.
· Circuit (Series)
· A circuit that has only one path for the flow of current. Batteries arranged in series are connected with negative of the first to positive of the second, negative of the second to positive of the third, etc. If two 12-volt batteries of 50 ampere-hours capacity each are connected in series, the circuit voltage is equal to the sum of the two battery voltages, or 24 volts, and the ampere-hour capacity of the combination is 50 ampere-hours.
· CCA
· Cold Cranking Amps is a rating used in the battery industry to define a battery’s ability to start an engine in cold temperatures. A great amount of amperes is needed to start the engine, but only for a short time.The actual rating is the number of amps that can be removed from a new fully charged battery at 0°F for 30 seconds while maintaining a voltage of at least 7.2 volts (for a 12-volt battery).As a battery ages with use, it may no longer be able to meet its original CCA rating.The higher the CCA rating, the greater the starting power of the battery.
· Deep-Cycle Battery
· Battery that provides a steady amount of current over a long period of time, provides a surge when needed and is designed to be deeply discharged over and over again.